Answers taken from this manual. Each one links to the page it comes from.

What does CLN-FIL mean on the display?

It means the condensing temperature has reached 140 °F or greater; at 160 °F, the compressor shuts off, restarting below 140 °F. The alarm resets when the liquid line temperature drops to 120 °F.

Manual: page 12

What happens when the cabinet temperature rises above its set temperature?

The microprocessor control starts the compressor, while the evaporator fan remains on.

Manual: page 11

Why is condensation forming around the drawers?

A faulty drawer perimeter heater may permit condensation because this heater is intended to prevent it. Have an authorized Traulsen service agent inspect it.

Manual: page 12, page 15

What part number is listed for the door gasket?

341-60197-00 is the listed part number for the Door Gasket.

Manual: page 14

The unit runs continuously. Could a drawer gasket be the cause?

Yes. A drawer gasket that requires replacement is listed as a possible cause of continuous unit operation.

Manual: page 13

How do I reverse the door on my Traulsen undercounter refrigerator?

Yes, the doors are field re-hingeable; contact Traulsen Service Department at 800-825-8220 for re-hinge instructions.

Manual: page 5

Similar Traulsen commercial refrigeration

Traulsen TU044HTModel family TU044HTOwner's Manual24 pages
Traulsen TU044HTModel family TU044HTService Manual12 pages
Traulsen G10000Service Manual78 pages
Traulsen AHT126WPUT-FHGService Manual40 pages
Traulsen G13010Service Manual32 pages
Traulsen AHT126WPUT-FHGOwner's Manual26 pages
Traulsen G10000Owner's Manual24 pages
Traulsen G10000Owner's Manual20 pages
All Traulsen commercial refrigeration →