Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before usetwice the time it has been laying down (up to four (4) hours), or 24 hoursIf the appliance was laid on its back or side, wait twice the time it was down, up to four (4) hours. If this exceeds four (4) hours, wait 24 hours.p. 11
Time to cool down24 hoursBefore usage, run the appliance empty to verify proper operationTypical for commercial refrigeration: 1 to 24 hoursp. 17
Clearance above3" (76.2 mm)T-23DTTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 9
Clearance at the sides0" (0 mm)T-23DTTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 9
Clearance behind3" (76.2 mm)T-23DTTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 9
Room temperature rangeless than 60 °F (15.5 °C) and no greater than 104 °F (40 °C)Proper operationTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 8

True T-23DT questions

Answers taken from this manual. Each one links to the page it comes from.

How long should I run the refrigerator before loading products?

Run the appliance empty for 24 hours before loading products, to verify proper operation.

Manual: page 17

What ambient temperature range does the T-23DT require?

For proper operation, room temperature must range from 60 °F (15.5 °C) through 104 °F (40 °C).

Other brands: Other not higher than 38℃ · Summit above 44 °F (7 °C) and below 90 °F (32 °C) · EdgeStar 50 °F to 90 °F (10 °C, 32 °C) Compare all

Manual: page 8

How do I clean the door gasket?

Clean the gasket with warm soapy water. Avoid sharp tools, knives, and full-strength cleaning products.

Manual: page 26

What does dEF mean on the display?

dEF means the appliance is defrosting. The display may briefly continue showing dEF after defrost ends.

Manual: page 19

How long should I wait before powering on a refrigerator laid on its side?

Leave it upright for twice the time it was down, up to four (4) hours; if longer, wait 24 hours.

Other brands: Other 24 hours · Summit about 2 hours · Whynter about 4 hours Compare all

Manual: page 11

How do I connect or remove the power cord?
  1. Fully insert the power cord into the appliance receptacle until it locks.
  2. To remove the plug, depress the red button.

Manual: page 10

How do I level the T-23DT?

Use a level to check the appliance front-to-back and side-to-side, then adjust the supports as needed.

  1. Position the appliance in its final installation location.
  2. Place a level inside near the doors, parallel to the front, and level the appliance.
  3. Check the inside rear, then both sides, positioning the level parallel to each surface.
  4. For leveling legs, support the low end and turn the bottom stems with an adjustable wrench.
  5. For castors, loosen the low-end castor bolt and insert the provided shims.
  6. Use no more than four shims per castor, with multiple shim slots offset.
  7. Tighten and secure the shims and castors, then verify the appliance is level.
  8. Verify the center leveling screws fully contact the floor.

Manual: page 13, page 14, page 15

True T-23DT compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

True T-23DTEdgeStar VBM101SSKoolmore KM-FMD12SGDMaster-Bilt Commercial Refrigerator
Time to cool down24 hoursat least 24 hoursabout 1 hourat least 6 hours
Clearance above3" (76.2 mm)1/2”over 4 inches (10.2 cm)4”
Clearance at the sides0" (0 mm)1/2”at least 4 inches (10.2 cm)0”
Clearance behind3" (76.2 mm)3/4”3 inches (7.6 cm)4”

Similar True commercial refrigeration

True T-12-HCModel family T12HCInstallation & Operation Manual40 pages
True T-23DT-G-HC~FGD01Model family T23DTInstallation & Operation Manual32 pages
True T-23DF-HCModel family T23DInstallation Manual32 pages
True T-23-HCModel family T23Service Manual36 pages
True TSCI-150PR-SWG-RInstallation Manual68 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True TBR32-RISZ1-L-B-S-1Installation Manual56 pages
All True commercial refrigeration →