Turbo Air error codes
4 Turbo Air error and alarm codes from 1 manual: what each code means and what the manual says to do.
4 codes1 manual
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| C1 | Compressor cycle malfunction: D sensor exceeds 32 °F after 30 minutes of compressor operation. | Normal operation resumes, with the compressor controlled automatically by the F sensor. | TGF-49F |
| D1 | D sensor malfunction, caused by a shorted or disconnected sensor. | Attempt defrosting; heater switches off above 28.4 °F, or runs 20 minutes if F sensor also fails. | TGF-49F |
| F1 | F sensor malfunction, caused by a shorted or disconnected sensor. | Compressor cycles 30 minutes on and 5 minutes off until repaired. | TGF-49F |
| F3 | Defrost malfunction: D sensor fails to reach 47 °F within 40 minutes. | Run the defrost heater for 40 minutes; switch it off immediately when D sensor reaches 47 °F. | TGF-49F |