Have a question about the Turbo Air PRO-12-2R-N? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 37 °F (3 °C)RefrigeratorsTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 14 |
|---|---|---|
| Fridge adjustment range | 27 °F to 50 °F (-3 °C, 10 °C)Refrigerators, adjustable settingTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 16 |
| Defrost | automaticRefrigerators | p. 14 |
Turbo Air PRO-12-2R-N questions
Answers taken from this manual. Each one links to the page it comes from.
What temperature settings and display range does the refrigerator have?
The refrigerator has these temperature settings and display limits.
| Function | Temperature |
|---|---|
| Default setting | 37 °F |
| Adjustable setting | 27 °F to 50 °F |
| Display range | 14 °F to 69 °F (-10˚C to +20˚C) |
Other brands: Other 32 °F (0 °C) to 41 °F (5 °C) · Liebherr b1 to b9 · Summit 36 °F/2 °C to 43 °F/6 °C Compare all
How do I set a lower refrigerator temperature?
Press the Down button to the desired temperature.
Manual: page 16
Why are there water drops inside or outside the unit?
- Humid rainy-season air. Wipe exterior drops with a dry cloth.
- Frequent or prolonged door opening. Keep the door closed to remove interior drops.
- Damp food is stored. Keep the door closed to remove interior drops.
Manual: page 20
Can the defrost interval be changed?
Yes, unusual operating conditions can call for a different defrost interval, and a Turbo Air technician must make the adjustment.
Manual: page 19
How do I maintain the refrigerator door seal?
Clean the door gasket frequently so it continues sealing properly.
Manual: page 13
Do I need to start defrosting manually?
No. The factory-set electronic controller provides the defrost cycle.
Manual: page 19
Why does the compressor stop during defrost?
The defrost function pauses the compressor, so this condition is not a malfunction.
Manual: page 20
Turbo Air PRO-12-2R-N compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Turbo Air PRO-12-2R-N | Other Commercial Refrigerator | Liebherr Commercial Refrigerator | Summit SCR1156 | |
|---|---|---|---|---|
| Fridge factory setting | 37 °F (3 °C) | 34 °F to 38 °F (1 °C, 3 °C) | b5 | 38 °F (3 °C) |
| Fridge adjustment range | 27 °F to 50 °F (-3 °C, 10 °C) | 34 °F to 38 °F (1 °C, 3 °C) | b1 to b9 | 36 °F to 43 °F (2 °C, 6 °C) |
Similar Turbo Air commercial refrigeration
| Turbo Air PRO-26-2RModel family PRO262R | User Manual | 18 pages |
|---|---|---|
| Turbo Air PRO-26-2R-G-PT-NModel family PRO262RG | Service Manual | 27 pages |
| Turbo Air PRO-26-2FModel family PRO262F | Service Manual | 54 pages |
| Turbo Air TGF-49F | Service Manual | 128 pages |
| Turbo Air TSF-23SD | Service Manual | 53 pages |
| Turbo Air M3F24-1 | Service Manual | 46 pages |
| Turbo Air TSF-23SD | Service Manual | 46 pages |