Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Clearance above | 31,5” (80 cm) (31.5 in) needs more space than mostminimum clearance from the ceilingTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 12 |
|---|---|---|
| Clearance at the sides | 11,8” (30cm) needs more space than mostminimum clearance from wallsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 12 |
U-Line UCFZ527-SS31A questions
Answers taken from this manual. Each one links to the page it comes from.
What devices can set up the Wi-Fi module?
Any PC, phone, or tablet can set up the Wi-Fi module, regardless of its operating system. The controller uses the EVlink Wi-Fi dongle for cloud connection.
Manual: page 28
Does the door close by itself?
Yes, the doors use an automatic return device and magnetic seal elements.
Manual: page 6
Where are the controls and cooling units located?
The equipment instruments are on the front panel; the motor and evaporator units are on top of the body.
Manual: page 6
Why does the compressor turn on and off during cooling?
The compressor starts when temperature rises above the set point by the differential, then stops after reaching the set point again. This cooling regulation applies after setting a product-storage temperature within the model's operating range.
Manual: page 16
What happens if the temperature probe fails?
A faulty probe changes compressor control to timed activation using parameters C4 and C5.
Manual: page 16
How do I dispose of this refrigerator?
Use a local municipal collection point for recycling, not unsorted municipal waste. Dispose of the unit under the laws in your country.
Manual: page 14
What operating temperature can the controller handle?
From -5 °C to 55 °C (from 23 to 131 °F).
Manual: page 15
How much clearance does this refrigerator need above and beside it?
Leave the specified minimum space from the walls and ceiling.
| Location | Minimum clearance |
|---|---|
| Walls | 11,8” (30cm) |
| Ceiling | 31,5” (80 cm) |
Manual: page 12
U-Line UCFZ527-SS31A compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| U-Line UCFZ527-SS31A | Other Commercial Refrigerator | Summit FF64BCSS | True GDM-05-HC-LD | |
|---|---|---|---|---|
| Clearance above | 31,5” (80 cm) (31.5 in) | 12" (30.5 cm) | 4“(102mm) | 12" Open (30.5 cm) |
| Clearance at the sides | 11,8” (30cm) | 2" (5.1 cm) | 5” (127mm) | 1" (25.4 mm) |
Similar U-Line commercial refrigeration
| U-Line UCRE524-SS33AModel family UCRE52 | User Manual | 48 pages |
|---|---|---|
| U-Line UCRE524-SG33AModel family UCRE52 | User Manual | 48 pages |
| U-Line UCRE518-SS33AModel family UCRE5 | User Manual | 48 pages |
| U-Line UCRE518-SG33AModel family UCRE5 | User Manual | 48 pages |
| U-Line UCRE515-SG33AModel family UCRE5 | User Manual | 48 pages |
| U-Line UCRE515-SS33AModel family UCRE5 | User Manual | 48 pages |
| U-Line UCWC518-SS33A | User Manual | 49 pages |
| U-Line UCWC524-SS33A | User Manual | 49 pages |