Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Door-open alarm after5 minuteswhen the door is left openTypical for commercial refrigeration: 1 to 5 minutesp. 40
Clearance abovedoes not require additional air spaceBuilt-in installationTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 8
Clearance at the sidesdoes not require additional air spaceBuilt-in installationTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 8
Clearance behinddoes not require additional air spaceBuilt-in installation; clearance is required for an electrical connection in the rearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 8
Defrostautomaticp. 27

U-Line UCWC518-SS33A questions

Answers taken from this manual. Each one links to the page it comes from.

How do I check the refrigerator’s actual internal temperature?
  1. Partially fill a plastic, nonbreakable bottle with water.
  2. Insert an accurate thermometer into the bottle.
  3. Tighten the bottle cap securely.
  4. Place the bottle in the desired area for 24 hours.
  5. Avoid opening the unit during the testing period.
  6. After 24 hours, check the water temperature and adjust the control slightly if needed.

Manual: page 28

Why is frost forming inside the unit?

A door that fails to seal can cause frost; check that it closes and seals fully.

Manual: page 27

Why is moisture appearing on the outside?

Excess humidity causes outside moisture; it should fade as humidity levels decrease.

Manual: page 27

Why is the refrigerator not cooling?
  • Compressor overheating. Check condenser airflow and cleanliness, then confirm the condenser fan operates.
  • Control set too cold. Adjust the Set Point Temp accordingly.

Manual: page 39

Why is the ice maker producing less ice?

Higher ambient temperatures can reduce ice production on applicable models. Keep the unit out of direct sunlight and away from heat-generating equipment.

Manual: page 6

What clearance does a built-in installation need?

No additional air space is needed at the top, sides, or rear for built-in installation. Do not obstruct the front grille, and provide clearance for the rear electrical connection.

Manual: page 8

Can I install the unit behind a closed cabinet door?

No. The unit cannot be installed behind a closed cabinet door.

Manual: page 8

How do I clear the stored error log?
  1. Select 15. Clear error log in service mode.
  2. When CLR flashes, press and hold the light key for 5 seconds.
  3. Release the key after the log is cleared.

Manual: page 42, page 43

Error codes in this manual

CodeMeaningWhat to do
E0Upper door 1 is open.p. 42
E1Thermistor 1 is open.p. 42
E2Thermistor 2 is open.p. 42
E3Thermistor 3 is open.p. 43
E4Thermistor 4 is open.p. 43
E5Thermistor 1 is shorted.p. 43
E6Thermistor 2 is shorted.p. 43
E7Thermistor 3 is shorted.p. 43
E8Thermistor 4 is shorted.p. 43
E9Lower door 2 is open.p. 43
P1Pump circuit is open.p. 43
All U-Line error codes →

Similar U-Line commercial refrigeration

U-Line UCWC518-SG33AModel family UCWC518SUser Manual49 pages
U-Line UCWC515-SG33AModel family UCWC51User Manual49 pages
U-Line UCWC515-SS33AModel family UCWC51User Manual49 pages
U-Line UCWC524-SS33AModel family UCWC5User Manual49 pages
U-Line UCWC524-SG33AModel family UCWC5User Manual49 pages
U-Line UCRE518-SS33AUser Manual48 pages
U-Line UCRE518-SG33AUser Manual48 pages
U-Line UCRE515-SG33AUser Manual48 pages
All U-Line commercial refrigeration →