Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Door-open alarm after5 minutesdoor left open longer than this timeTypical for commercial refrigeration: 1 to 5 minutesp. 39
Clearance aboveno additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 8
Clearance at the sidesno additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 8
Clearance behindno additional air spacebuilt-in installationTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 8
DefrostAutomatic Defrostp. 26
Room temperature range50 °F (10 °C) and 100 °F (38 °C)This unitTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 6
Sabbath modeYeswhen the unit is cooling but the interior light does not illuminatep. 26

U-Line UCRE515-SG33A questions

Answers taken from this manual. Each one links to the page it comes from.

How do I check the refrigerator’s actual product temperature?

Use a capped, water-filled bottle and thermometer to measure the product temperature after 24 hours.

  1. Partially fill a plastic, nonbreakable bottle with water.
  2. Insert an accurate thermometer and tighten the bottle cap securely.
  3. Place the bottle in the desired area for 24 hours.
  4. Avoid opening the unit during the test.
  5. After 24 hours, check the water temperature.
  6. If needed, adjust the temperature control in a small increment.

Manual: page 27

Why is there frost inside or condensation outside my U-Line unit?
  • Door seal or closing problem. Check that the door closes and seals properly.
  • Excessive humidity. Moisture should dissipate as humidity levels decrease.

Manual: page 26

The refrigerator is not cooling, but its lights work. How do I exit showroom mode?

Hold Light Button and Power Button together for 5 seconds to enter or exit SHOWROOM MODE.

  1. Watch for one display flash and a beep.
  2. When the degree symbol flashes, the compressor and fans can operate outside demonstration mode.

Manual: page 40

Why is ice production lower in a warm room?

On applicable models, higher ambient temperatures can reduce ice production; this unit operates between 50 °F (10 °C) and 100 °F (38 °C).

Manual: page 6

Can I install the unit behind a closed cabinet door?

No. The unit cannot be installed behind a closed cabinet door.

Manual: page 8

How do I clear the error log?

Hold the light key for 5 seconds while CLR flashes.

Manual: page 41, page 42

Error codes in this manual

CodeMeaningWhat to do
E0Upper door 1 is open.p. 41
E1Thermistor 1 is open.p. 41
E2Thermistor 2 is open.p. 41
E3Thermistor 3 is open.p. 41
E4Thermistor 4 is open.p. 42
E5Thermistor 1 is shorted.p. 42
E6Thermistor 2 is shorted.p. 42
E7Thermistor 3 is shorted.p. 42
E8Thermistor 4 is shorted.p. 42
E9Lower door 2 is open.p. 42
P1Pump circuit is open.p. 42
All U-Line error codes →

U-Line UCRE515-SG33A compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

U-Line UCRE515-SG33AOther 9301F-290Summit SPR627OSTrue TGO-27-POP01
Door-open alarm after5 minutes2 minutesmore than 60 seconds5 minutes
Room temperature range50 °F (10 °C) and 100 °F (38 °C)70-100 °F (-73 °C)44ºF and 90ºF (7ºC to 32ºC)60 °F (15.5 °C)

Similar U-Line commercial refrigeration

U-Line UCRE515-SS33AModel family UCRE515SUser Manual48 pages
U-Line UCRE518-SS33AModel family UCRE51User Manual48 pages
U-Line UCRE518-SG33AModel family UCRE51User Manual48 pages
U-Line UCRE524-SS33AModel family UCRE5User Manual48 pages
U-Line UCRE524-SG33AModel family UCRE5User Manual48 pages
U-Line UCRE552-SS61AModel family UCRE5User Manual37 pages
U-Line UCFZ527-SS31AModel family UCFZ5User Manual30 pages
U-Line UCWC518-SS33AUser Manual49 pages
All U-Line commercial refrigeration →