Atosa error codes

25 Atosa error and alarm codes from 3 manuals: what each code means and what the manual says to do.

25 codes3 manuals

Codes and what they mean

As described in each manual. The same code can mean different things on different models, so check the model column.

CodeMeaningWhat to doManual
chtThe condenser is dirty, with a preliminary alarm.Commercial Refrigerator
dADoor openCompressor and fans restartISU5S-03II
dFDefrost is currently running.Commercial Refrigerator
dOrThe door is open.Commercial Refrigerator
E0Control probe 1 has failed.Commercial Refrigerator
E1Defrost probe 2 has failed.Commercial Refrigerator
E1Condenser temperature sensor is disconnected or detects no change during ice making.Check the condenser probe connection and refrigeration system; contact SKS.YDS0350A-161
E2Condenser probe 3 has failed.Commercial Refrigerator
E2Ice harvesting takes too long.Adjust ice thickness, verify the harvest valve opens fully, and contact SKS.YDS0350A-161
E3Water temperature sensor is disconnected.Check the water temperature sensor connection and contact SKS.YDS0350A-161
E4Condenser temperature is too high.Improve heat dissipation, clean the condenser if clogged, and contact SKS.YDS0350A-161
E5Water shortage protection is active.Check water pressure, inlet valve, level probe, and drain valve; contact SKS.YDS0350A-161
E6High pressure protection is active.Improve heat dissipation, clean the condenser, check fans, and contact SKS.YDS0350A-161
E7Water temperature is too high.Check the inlet valve and water level probe; contact SKS.YDS0350A-161
E8Door magnetic switch is disconnected.Check the water curtain, magnetic door switch, and contact SKS.YDS0350A-161
EdDefrost stopped because its time limit expired.Commercial Refrigerator
EEThe unit parameters are invalid.Commercial Refrigerator
EFThe operating parameters are invalid.Commercial Refrigerator
EtCA clock alarm is active.Commercial Refrigerator
FULIce bin is full, so the ice maker stops operating.Remove ice from the storage bin and check the water curtain position.YDS0350A-161
HAMaximum temperature alarmOutputs unchangedISU5S-03II
HIThe temperature is too high.Commercial Refrigerator
IAAn external alarm is active.Commercial Refrigerator
LAMinimum temperature alarmOutputs unchangedISU5S-03II
LOThe temperature is too low.Commercial Refrigerator
P1Room probe failureCompressor follows configured controlISU5S-03II
P2Evaporator probe failureDefrost end is timedISU5S-03II

Error codes of other brands