Atosa error codes
25 Atosa error and alarm codes from 3 manuals: what each code means and what the manual says to do.
25 codes3 manuals
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| cht | The condenser is dirty, with a preliminary alarm. | Commercial Refrigerator | |
| dA | Door open | Compressor and fans restart | ISU5S-03II |
| dF | Defrost is currently running. | Commercial Refrigerator | |
| dOr | The door is open. | Commercial Refrigerator | |
| E0 | Control probe 1 has failed. | Commercial Refrigerator | |
| E1 | Defrost probe 2 has failed. | Commercial Refrigerator | |
| E1 | Condenser temperature sensor is disconnected or detects no change during ice making. | Check the condenser probe connection and refrigeration system; contact SKS. | YDS0350A-161 |
| E2 | Condenser probe 3 has failed. | Commercial Refrigerator | |
| E2 | Ice harvesting takes too long. | Adjust ice thickness, verify the harvest valve opens fully, and contact SKS. | YDS0350A-161 |
| E3 | Water temperature sensor is disconnected. | Check the water temperature sensor connection and contact SKS. | YDS0350A-161 |
| E4 | Condenser temperature is too high. | Improve heat dissipation, clean the condenser if clogged, and contact SKS. | YDS0350A-161 |
| E5 | Water shortage protection is active. | Check water pressure, inlet valve, level probe, and drain valve; contact SKS. | YDS0350A-161 |
| E6 | High pressure protection is active. | Improve heat dissipation, clean the condenser, check fans, and contact SKS. | YDS0350A-161 |
| E7 | Water temperature is too high. | Check the inlet valve and water level probe; contact SKS. | YDS0350A-161 |
| E8 | Door magnetic switch is disconnected. | Check the water curtain, magnetic door switch, and contact SKS. | YDS0350A-161 |
| Ed | Defrost stopped because its time limit expired. | Commercial Refrigerator | |
| EE | The unit parameters are invalid. | Commercial Refrigerator | |
| EF | The operating parameters are invalid. | Commercial Refrigerator | |
| EtC | A clock alarm is active. | Commercial Refrigerator | |
| FUL | Ice bin is full, so the ice maker stops operating. | Remove ice from the storage bin and check the water curtain position. | YDS0350A-161 |
| HA | Maximum temperature alarm | Outputs unchanged | ISU5S-03II |
| HI | The temperature is too high. | Commercial Refrigerator | |
| IA | An external alarm is active. | Commercial Refrigerator | |
| LA | Minimum temperature alarm | Outputs unchanged | ISU5S-03II |
| LO | The temperature is too low. | Commercial Refrigerator | |
| P1 | Room probe failure | Compressor follows configured control | ISU5S-03II |
| P2 | Evaporator probe failure | Defrost end is timed | ISU5S-03II |