Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting38º FFactory setting for the refrigerator cabinetTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 10
Clearance above12 inPRI2HC-1AS, topTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 7
Clearance at the sides0 inPRI2HC-1AS, left and right sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 7
Clearance behind0 in needs less space than mostPRI2HC-1AS, rearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 7
DefrostmanualPRI refrigeratorp. 13
Room temperature range60º F to 100º FIndoor, controlled environmentTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 5

Beverage-Air PRI2HC-1AS****** questions

Answers taken from this manual. Each one links to the page it comes from.

Why does the refrigerator run constantly but stay cold?
  • Dirty condenser. Clean the condenser.
  • Iced evaporator. Defrost the evaporator.
  • High room temperature. Lower the room temperature.
  • Temperature control problem. Adjust or replace the control.

Manual: page 23

What are the cabinet dimensions for the PRI2HC-1AS refrigerator?

68 7/8 x 36 1/8 x 84 3/8 in.

Manual: page 6

How do I start a manual defrost?

Quickly press and release DEFROST (ESC) to activate manual defrost.

Manual: page 13

What does dEF mean on the display?

dEF means the unit is defrosting, so no action is needed during normal operation.

Manual: page 11

The refrigerator has no cooling and is silent. What should I check?
  • No power connection. Connect the refrigerator to the proper voltage circuit.
  • Tripped fuse or circuit breaker. Replace the fuse or reset the breaker.
  • Loose power plug. Check the outlet connection and replace it as needed.

Manual: page 23

What does the Alarm LED mean?

The Alarm LED shows these alarm states.

Alarm LED stateMeaning
On fixedALARM Present
FlashingALARM Silenced
OffNo Alarm

Manual: page 13

Beverage-Air PRI2HC-1AS****** compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Beverage-Air PRI2HC-1AS******Other Commercial RefrigeratorSummit FF64BCSSGram Commercial Refrigerator
Fridge factory setting38º F34 °F to 38 °F (1 °C, 3 °C)38 °F/3 °C5 °C (41 °F)
Clearance above12 in12" (30.5 cm)4“(102mm)250 mm (9.8 in)
Clearance at the sides0 in2" (5.1 cm)5” (127mm)20 mm (0.8 in)
Clearance behind0 in2" (5.1 cm)5” (127mm)max. 75 mm (3 in)
Room temperature range60º F to 100º Fbelow 90 °F (32 °C)above 44 °F (7 °C) and below 90 °F (32 °C)+16C and +40 °C (104 °F)

Similar Beverage-Air commercial refrigeration

Beverage-Air PR3HC-1A*S******Installation & Operation Manual54 pages
Beverage-Air BF200RB-PFO-XLOperating Instructions74 pages
Beverage-Air MT08-1[#]User Manual69 pages
Beverage-Air BB58HC****G*******Installation & Operation Manual46 pages
Beverage-Air DD58HC****G*******Installation & Operation Manual39 pages
Beverage-Air 3071629RV05Operating Instructions39 pages
Beverage-Air UCRFOperating Instructions34 pages
Beverage-Air WTR*41AHC*********Installation & Operation Manual32 pages
All Beverage-Air commercial refrigeration →