Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting38.0FAll models, factory settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 6
Clearance above0" (0 cm)Top clearanceTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 7
Clearance at the sides0" (0 cm)Left and right clearanceTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 7
Clearance behind3" (7.6 cm)Rear clearanceTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 7
Defrostautomatically defrost as neededp. 11

Beverage-Air RI18HC***G******** questions

Answers taken from this manual. Each one links to the page it comes from.

Why does the refrigerator run almost all the time?
  • Dirty condenser. Clean the condenser.
  • Iced evaporator. Defrost the evaporator.
  • Room temperature is high. Lower the room temperature.

Manual: page 23

How much clearance does the refrigerator need around it?

Allow 0" at the top and sides, and 3" at the rear and below.

Manual: page 7

What are the cabinet dimensions for the RI18HC models?

Cabinet dimensions include casters and vary by door and glass configuration.

ModelCabinet size (w x d x h, Inches)
RI18HC27 1/4 x 29 1/8 x 72 1/4
RI18HC-HS27 1/4 x 29 1/8 x 72 3/8
RI18HC-G27 1/4 x 29 1/8 x 72 1/4
RI18HC-HG27 1/4 x 29 1/8 x 72 3/8
RI18HC-HGS27 1/4 x 29 1/4 x 72 3/8

Manual: page 6

How do I start a manual defrost?

Press and release DEFROST (ESC) quickly to start a manual defrost.

Manual: page 13

What does dEF mean on the display?

dEF means the unit is defrosting; this is normal operation, so do nothing.

Manual: page 11

What should I check when the refrigerator is silent and not cooling?
  • Power connection. Connect the unit to the proper voltage circuit.
  • Tripped protection. Replace the fuse or reset the circuit breaker.
  • Loose plug. Check the outlet connection and replace it as needed.

Manual: page 23

What do the alarm light states mean?
  • On fixed: ALARM Present means an alarm is active.
  • Flashing: ALARM Silenced means the alarm has been silenced.
  • Off: No Alarm means no alarm is present.

Manual: page 13

Beverage-Air RI18HC***G******** compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Beverage-Air RI18HC***G********Other Commercial RefrigeratorSummit AL57GGram Commercial Refrigerator
Fridge factory setting38.0F34 °F to 38 °F (1 °C, 3 °C)38 °F, or 3 °C5 °C (41 °F)
Clearance above0" (0 cm)12" (30.5 cm)2 to 3 mm (about 1/10")250 mm (9.8 in)
Clearance at the sides0" (0 cm)2" (5.1 cm)5 inches (127mm) (12.7 cm)20 mm (0.8 in)
Clearance behind3" (7.6 cm)2" (5.1 cm)5 inches (127mm) (12.7 cm)max. 75 mm (3 in)

Similar Beverage-Air commercial refrigeration

Beverage-Air RB19HC-1**G*******Installation & Operation Manual29 pages
Beverage-Air BF200RB-PFO-XLOperating Instructions74 pages
Beverage-Air MT08-1[#]User Manual69 pages
Beverage-Air PR3HC-1A*S******Installation & Operation Manual54 pages
Beverage-Air BB58HC****G*******Installation & Operation Manual46 pages
Beverage-Air DD58HC****G*******Installation & Operation Manual39 pages
Beverage-Air 3071629RV05Operating Instructions39 pages
Beverage-Air UCRFOperating Instructions34 pages
All Beverage-Air commercial refrigeration →