Have a question about the Fagor Commercial Refrigerator? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 32 °F (0 °C) colder than mostElectronic-control refrigerators, factory default set pointTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 16 |
|---|---|---|
| Fridge adjustment range | ‐1 °C (30 °F) to 5 °C (40 °F)Electronic-control refrigeratorsTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 17 |
| Freezer factory setting | ‐8 °F (-13 °C) warmer than mostElectronic-control freezers, factory default set pointTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C) | p. 16 |
| Freezer adjustment range | ‐23 °C (‐8 °F) to ‐16 °C (2 °F)Electronic-control freezersTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 17 |
| Wait before use | 24 hoursAfter lifting the unit upright before plugging into power | p. 14 |
| Time to cool down | three minutes faster than mostAfter connecting an electronic-control freezer or refrigerator, before cooling startsTypical for commercial refrigeration: 1 to 24 hours | p. 16 |
| Clearance at the sides | three inchesAirflow space along the sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 18 |
| Clearance behind | three inchesAirflow space along the backTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 18 |
Fagor Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
How do I clean the door gasket?
- Wash the gasket with warm, soapy water.
- Do not use chemical cleaners, sharp tools, or knives on it.
Manual: page 20
How do I replace the door gasket?
- Pull the old gasket toward you to remove it.
- Press the replacement into the door groove until it snaps into place.
Manual: page 20
How do I start and stop manual defrost?
- Hold the DOWN arrow for 5 seconds; the snowflake icon appears.
- Wait until the snowflake icon is solid, indicating Defrost mode.
- To stop, hold the DOWN arrow for 5 seconds; wait 2 minutes for compressor startup.
Manual: page 18
The unit is not reaching its set temperature. What should I check?
- Automatic defrost is running. The cycle is time initiated and temperature terminated.
- Airflow is blocked. Leave three inches of space along the front, back, and sides.
- The evaporator iced up after early loading. Run the unit at least 24 hours before adding product.
Manual: page 18
How long should the unit remain upright before I plug it in?
Leave the cabinet upright for 24 hours before plugging it into the power source.
Other brands: Other 24 hours · Summit about 2 hours · True 24 hours Compare all
Manual: page 14
Why does the unit display temperature but not start cooling immediately?
The compressor and fan icons flash for three minutes after connection; cooling starts after this delay. Turn the rocker switch ON to start the unit, then check for temperature-controller alarms or error codes.
Other brands: Other 5-6 hours · True 24 hours · Fisher & Paykel 2 to 3 hours Compare all
Manual: page 16
How do I level the refrigerator or freezer?
- Place the unit in its final location and check level front to back and side to side.
- Insert leveling shims between each castor and the frame rail.
- With multiple shims, rotate adjacent slots 90 degrees so they do not line up.
- Tighten each castor's bearing race clockwise using the provided tool.
- Lock the front castors so the cabinet cannot move.
- Check that the drain hose is inside the drain pan.
Manual: page 14
What electrical connection do these refrigerators use?
The listed models use 115 / 60 and a NEMA 5‐15P plug.
Manual: page 5
Fagor Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Fagor Commercial Refrigerator | Other Commercial Refrigerator | Gram Commercial Refrigerator | Maxx Cold MCF-23FDHC | |
|---|---|---|---|---|
| Fridge factory setting | 32 °F (0 °C) | 34 °F to 38 °F (1 °C, 3 °C) | 5 °C (41 °F) | 35 °F (2 °C) |
| Fridge adjustment range | ‐1 °C (30 °F) to 5 °C (40 °F) | 34 °F to 38 °F (1 °C, 3 °C) | 2 to 12 °C (36 to 54 °F) | 28 °F to 39 °F (-2.2 °C to -3.9 °C) |
| Freezer factory setting | ‐8 °F (-13 °C) | -7°Fto -1 °F (-22 °C, -18 °C) | -18 °C (0 °F) | 0 °F (18 °C) |
| Freezer adjustment range | ‐23 °C (‐8 °F) to ‐16 °C (2 °F) | -7°Fto -1 °F (-22 °C, -18 °C) | -10 to -22 °C (14 to -8 °F) | -10 °F to -5 °F (-23.3 °C to -20.6 °C) |
| Wait before use | 24 hours | at least 24 hours | at least 2 hours | at least 24 hours |