Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before useat least 2 hoursAfter horizontal transport, before starting the productp. 6
Room temperature range+16C and +40 °C (104 °F)Operating ambient temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 7

Gram Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

Can I use this appliance to chill or freeze food?

No. It is for storing food at a constant temperature, not for chilling or freezing food.

Manual: page 4

When does the door close by itself?

It closes automatically below 90°, but stays open when opened beyond 90°.

Manual: page 23

How long must the cabinet stand upright after horizontal transport?

At least 2 hours, so compressor oil can return before starting the product.

Manual: page 6

How do I connect the appliance to power?

Use only the supplied cord, never an extension cord; have an electrician install a nearer wall socket if needed.

Manual: page 10

How long should I wait before turning the appliance on again?

Wait minimum 3 minutes before turning it on again to protect the compressor.

Manual: page 11

How do I prepare an old cabinet for collection in the United Kingdom?

Collection is available only when a new cabinet is delivered at the same time.

  1. Fully defrost the old cabinet.
  2. Empty it before collection.

Manual: page 26

Error codes in this manual

CodeMeaningWhat to do
A1 / OPThe door remains open or is not closed correctly.Press P to confirm the alarm.p. 14
A2The cabinet has a high internal temperature.Press P to confirm the alarm.p. 14
A4The cabinet has a high external temperature.Press P to confirm the alarm.p. 14
F1The room temperature sensor has failed.Request service assistance.p. 15
F2The evaporator temperature sensor has failed.Request service assistance.p. 15
F3*Condenser sensor 1 has failed.Request service assistance.p. 15
F4*Condenser sensor 2 has failed.Request service assistance.p. 15
F7*The condenser temperature is too high.Check for a clogged condenser or excessive ambient heat. Improve ventilation; request service if unresolved.p. 15
FILTERThe condenser air filter needs cleaning.Clean the air filter, then press the indicated key three times and P three times to reset.p. 15
OPThe door is open.Press P to confirm the alarm.p. 14
All Gram error codes →

Gram Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Gram Commercial RefrigeratorOther Commercial RefrigeratorSummit AL57GWhynter CBM-815WS
Wait before useat least 2 hoursat least 24 hoursat least 2 hoursabout 4 hours
Room temperature range+16C and +40 °C (104 °F)below 90 °F (32 °C)72º and 78ºF (23º-26ºC)72º- 78ºF / 23º26ºC

Similar Gram commercial refrigeration

Gram Commercial Refrigeration Instruction ManualInstruction Manual154 pages
Gram Commercial Refrigeration User ManualUser Manual140 pages
Gram IO-REF-1455Instruction Manual132 pages
Gram Commercial Refrigeration Instruction ManualInstruction Manual131 pages
Gram COMPACT 600 Gram RefrigeratorUser Manual124 pages
Gram IO-REF-1453Instruction Manual124 pages
Gram IO-REF-1421Instruction Manual120 pages
Gram IO-REF-1419Operating Instructions120 pages
All Gram commercial refrigeration →