Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance behind4-inch (102 mm) needs more space than mostBetween the rear of the merchandiser and the wallTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 5

Hussmann Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What factory discharge-air temperatures does the case use?

Factory discharge-air settings differ by case temperature class.

Case classFactory setting
Low temperature-3 °F
Medium temperature37 °F

Manual: page 27

Does the CoreLink controller need temperature adjustments?

No. The CoreLink Electronic Controller is factory programmed for the required parameters, but check its program at startup. Use the display case data sheet for the setpoint and discharge-air temperature.

Manual: page 27

How much space must remain behind the merchandiser?

Leave 4 inches (102 mm) behind the merchandiser for air circulation.

Other brands: Other 4” · Summit 5” (127mm) · True 1" (25.4 mm) Compare all

Manual: page 5

Can air conditioners or fans create airflow around the merchandiser?

No. Prevent air conditioning, fans, open doors, or windows from creating air currents around the merchandiser, because they can impair operation.

Manual: page 7

How do I restore the controller’s factory settings?
  1. Open the CoreLink user interface.
  2. Use the interface to force a factory reset.

Manual: page 28

What happens if the building automation network fails?

The controller uses its stored standalone or program settings and continues regulating the display case until the connection returns.

Manual: page 28

Why do the compressors start at different times?

Compressor startups are staggered to prevent high electrical circuit demand.

Manual: page 43

What should I check when the case makes an unusual sound?

Verify each fan is running and inspect for evaporator fan blade interference. Only Hussmann authorized personnel may service this equipment.

Manual: page 43

How do I level a merchandiser lineup?

Start at the store floor's highest point.

  1. Place shims under the rail at a base component, or crossbar.
  2. Shim bottom front supports that are not fully touching the floor.
  3. Do not place shims elsewhere, because uneven weight can cause leaks and door problems.

Manual: page 9