Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance above5.5 inch (140 mm)Between facade top and ceiling3 inches (76 mm)With a louvered Facade Panel kitTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 6
Room temperature range-40 to 120 °F Ambient (-40 to 49 °C)Factory Installed Operating Range-4 to 120 °F Ambient (-20 to 49 °C)Non-Factory Installed Operating RangeTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 56

Hussmann Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What ambient temperature range applies to the condensing unit?

The allowable ambient range depends on how the condensing unit was installed.

InstallationAmbient range
Factory Installed-40 to 120 °F ambient
Non-Factory Installed-4 to 120 °F ambient

Manual: page 56

What doorway opening is needed to move the case inside?

The required opening depends on the case model.

  • RFLNS and RFMNS cases: 36 in. x 80 in. minimum opening.
  • RFLTM cases: 44 in. x 87.5 in. minimum opening.
  • Door handles can be removed for narrow entrances.

Manual: page 8

How do I start a manual defrost?

Hold DEF for more than 2 seconds to start a manual defrost.

Manual: page 22

What should I do if the controller shows Err during hotkey programming?

Programming failed. Cycle power to restart the download process, and remove the hotkey to abort.

Manual: page 59

How do I reset counters during the controller's first five minutes?

Cycle power to the controller, because the Advanced Options Menu is locked for 5 minutes after power-up.

Manual: page 60

Error codes in this manual

CodeMeaningWhat to do
C01Discharge temperature trip.p. 65
C02System trip.p. 65
C03Short cycling.p. 65
C04Locked rotor.p. 65
C05Open circuit.p. 65
C06Missing phase or open start.p. 65
C07Reverse phase or open run.p. 65
C08Welded contactor.p. 65
C09Low voltage.p. 65
C10Communications were lost.p. 65
C11DLT sensor has failed.p. 65
CHCompressor working hour counter alarm is active.p. 65
CPACopeland PerformanceAlert is improperly connected.p. 65
dllDLT lock alarm is active.p. 65
dltDLT temperature alarm is active.p. 65
EEElectronic Unit Controller has failed.p. 65
FHFan working hour counter alarm is active.p. 65
HACondenser temperature is too high.p. 65
HdLMaximum alarm count has been reached.Reset the alarm counters.p. 65
HPHigh pressure trip occurred.p. 65
HPLHigh pressure trip lockout is active.p. 65
P1Suction probe has failed.p. 65
P2Condenser probe has failed.p. 65
P3DLT probe has failed.p. 65
PoFKeypad is locked.Press the indicated keys for more than three seconds to unlock it.p. 65
PonKeypad is unlocked.p. 65
All Hussmann error codes →

Hussmann Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Hussmann Commercial RefrigeratorOther Commercial RefrigeratorSummit AL57GTrue TUC-27F-HC
Clearance above5.5 inch (140 mm)12" (30.5 cm)2 to 3 mm (about 1/10")0" (0 mm)
Room temperature range-40 to 120 °F Ambient (-40 to 49 °C)below 90 °F (32 °C)72º and 78ºF (23º-26ºC)60 °F (15.5 °C) to 104 °F (40 °C)