Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance behind4 inches (102 mm)between the rear of the merchandiser and a wallTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 4

Hussmann Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How much space should I leave behind the merchandiser?

Leave 4 inches (102 mm) between the merchandiser’s rear and the wall for air circulation.

Other brands: Other 4” · Summit 5” (127mm) · True 1" (25.4 mm) Compare all

Manual: page 4

How is defrost scheduled on this case?

By time: the controller uses the programmed daily defrost count and termination, while BAS sets the defrost start time.

Manual: page 20

What ends defrost on a low-temperature case?

At 48 °F, a sensor at the evaporator coil’s left end ends defrost on low-temperature cases.

Manual: page 20

How do I restore the controller’s factory settings?

Open the user interface and force a factory reset in the CoreLink application.

Manual: page 21

How do I restart a compressor after a safety lockout?

After the failure is diagnosed and repaired, reboot the controller to clear the lockout and restart the compressor.

Manual: page 20