Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

DefrostOfftime Defrostp. 21

Hussmann Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What pilot-hole size is specified for the optional scale stand?

1/8-inch diameter pilot holes are specified through the metal liners. Do not drill beyond the liners.

Manual: page 17

What defrost method does this merchandiser use?

The merchandiser uses Offtime Defrost; control settings are listed in the data sheets.

Manual: page 21

Does the defrost termination thermostat need adjustment?

No. The standard disc type defrost termination thermostat is not adjustable.

Manual: page 21

How do I reset a tripped fluorescent-light ballast?

Turn the merchandiser light switch OFF before resetting the ballast.

  1. Check affected shelf plugs are fully seated and lamps are firmly seated in their holders.
  2. Turn the merchandiser light switch OFF for a minimum of 15 seconds.
  3. Turn the merchandiser light switch ON.

Manual: page 31

Can the LED lights be switched on in a cold environment?

Yes, EcoShine II LED lights can be turned on and off in cold environments with no warm-up time.

Manual: page 30

How do I prepare the front glass before fully raising it?

Set and level the case before making glass adjustments.

  1. Slowly raise and lower each glass section 6 times to 6 in. (152 mm).
  2. Raise the glass to about 12 in. (305 mm), then cycle it 6 times.
  3. Raise the glass to full extension, then lower it.

Manual: page 7

What power and startup behavior do the LED lights have?

LED lighting uses 24VDC power and can be switched in a cold case without warm-up time.

Manual: page 30

Why are two to four fluorescent lights out?
  • An arc was detected. Check affected shelf plugs and lamps, then switch off the merchandiser light switch for 15 seconds before turning it on.
  • A shelf plug or lamp is loose. Switch off the light, reseat the lamps and firmly reinsert each shelf plug, then switch it on.

Manual: page 31, page 32