Master-Bilt error codes
9 Master-Bilt error and alarm codes from 1 manual: what each code means and what the manual says to do.
9 codes1 manual
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| ALHi | High temperature alarm setpoint triggers the alarm and display message. | Commercial Refrigerator | |
| Er 1 | ERC software or hardware failure. | Cut power, correct the problem, then restore power to reset the display. | Commercial Refrigerator |
| Er 2 | ERC communication failure involving the display module cable. | Cut power, correct the problem, then restore power to reset the display. | Commercial Refrigerator |
| Er 3 | Zone temperature sensor is open or shorted. | Press UP or DOWN to reset it; replace the sensor if the message remains. | Commercial Refrigerator |
| Er 4 | Evaporator sensor is open or shorted. | Press UP or DOWN to reset it; replace the sensor if the message remains. | Commercial Refrigerator |
| Er 5 | ERC software or hardware failure. | Cut power, correct the problem, then restore power to reset the display. | Commercial Refrigerator |
| Er 6 | Temperature has fallen below the low alarm setpoint. | The error resets automatically when temperature returns within both setpoints. | Commercial Refrigerator |
| Er 7 | Temperature has risen above the high alarm setpoint. | The error resets automatically when temperature returns within both setpoints. | Commercial Refrigerator |
| Er 8 | Relay and display modules are incompatible. | Commercial Refrigerator |