Metalfrio error codes
24 Metalfrio error and alarm codes from 1 manual: what each code means and what the manual says to do.
24 codes1 manual
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| 15 | Excessive condenser heating. | Clear condenser obstructions, restore power, and check condenser fan operation. | NG26CHC |
| 17 | Main or condenser sensor failure. | Replace the temperature sensor; the system will not operate during the fault. | NG26CHC |
| 19 | Refrigeration failure. | Consult specialized technical service; restarting will not clear the fault. | NG26CHC |
| 20 | Low return air temperature below the set point. | NG26CHC | |
| 21 | Excessive compressor starts. | Check compressor connections and status parameter; inspect the compressor if needed. | NG26CHC |
| 22 | Triac S1 overcurrent. | Check the wiring. | NG26CHC |
| 23 | Triac S2 overcurrent. | Check the wiring. | NG26CHC |
| 27 | Other temperature sensor faults. | Replace the sensor; the system continues operating while ignoring the error. | NG26CHC |
| 28 | No blocking due to low temperature trend. | Check for an iced evaporator, low refrigerant, or low evaporator fan speed. | NG26CHC |
| CCP | Cold Climate Protection mode is active. | Resets automatically. | NG26CHC |
| cht | CO2 condenser high temperature pre alarm. | Resets automatically. | NG26CHC |
| dF | Defrost is in progress. | Resets automatically. | NG26CHC |
| dOr | Open door alarm. | Resets automatically. | NG26CHC |
| E0 | Regulation probe error. | Resets automatically. | NG26CHC |
| E1 | Second probe error. | Resets automatically. | NG26CHC |
| E2 | Door switch fault. | Resets automatically. | NG26CHC |
| E3 | Temperature mitigation algorithm is active. | Resets automatically. | NG26CHC |
| ECO | ECO mode is active. | Resets automatically. | NG26CHC |
| EE | Internal parameters error. | Reset is not possible. | NG26CHC |
| EF | Operating parameters error. | Reset manually. | NG26CHC |
| Err | Refrigerant system failure alarm. | Resets automatically. | NG26CHC |
| HI | High temperature alarm. | Resets automatically. | NG26CHC |
| hPr | CO2 high pressure pre alarm. | Resets automatically. | NG26CHC |
| LO | Low temperature alarm. | Resets automatically. | NG26CHC |