Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range-40 °C to +70 °C (-40 °F to +158 °F)Temperature control rangeTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 20
Time to cool downfour hoursbefore placing products inside or starting a defrost cycleTypical for commercial refrigeration: 1 to 24 hoursp. 8
Clearance at the sides6 in needs more space than mostMinimum clearance from side wallsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 3
Clearance behind15 cm (5.9 in) needs more space than mostWhen the cooler's rear part leans against a wall6 inMinimum clearance from back wallsTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 22 p. 3
DefrostautomaticCooler defrostp. 3

Metalfrio NG26CHC questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature control range does this cooler specify?

-40 °C to +70 °C (-40 °F to +158 °F).

Other brands: Other 32 °F (0 °C) to 41 °F (5 °C) · Liebherr b1 to b9 · Summit 36 °F/2 °C to 43 °F/6 °C Compare all

Manual: page 20

Why is my cooler not cooling properly?
  • Door open or leaking. Close the doors and check for air leaks.
  • Frequent door opening. Avoid opening the doors too far.
  • Poor product distribution. Rearrange products for free airflow; remove unrelated cardboard or plastic.
  • External heat. Move the cooler away from stoves and direct sunlight.
  • Rear against wall. Leave at least 15 cm from the wall.

Other brands: Other 4” · Summit 5” (127mm) · True 1" (25.4 mm) Compare all

Manual: page 22

Can I load products right after connecting the cooler?

No. Wait four hours after connection before loading, and cool products to room temperature first.

Manual: page 8

How do I install shelves while preserving camera clearance?

Begin with the lowest shelf; leave 3.14 in (80 mm) beside the lower-left camera.

  1. Set each shelf against the rear wall.
  2. Maintain 2.75 in (70 mm) clearance for the bottom and top cameras.
  3. Use one matching numbered slot for all clips, keeping the shelf level.

Manual: page 6

How do I level the cooler?
  1. Screw the leveling legs into the threaded inserts at each base corner.
  2. Use a spirit level to adjust the leveling feet until the cooler sits flat.
  3. Keep the distance from the floor as small as possible.
  4. Apply NSF-approved sealant along all four sides for complete closure.

Manual: page 4

Error codes in this manual

CodeMeaningWhat to do
15Excessive condenser heating.Clear condenser obstructions, restore power, and check condenser fan operation.p. 19
17Main or condenser sensor failure.Replace the temperature sensor; the system will not operate during the fault.p. 19
19Refrigeration failure.Consult specialized technical service; restarting will not clear the fault.p. 19
20Low return air temperature below the set point.p. 19
21Excessive compressor starts.Check compressor connections and status parameter; inspect the compressor if needed.p. 19
22Triac S1 overcurrent.Check the wiring.p. 19
23Triac S2 overcurrent.Check the wiring.p. 19
27Other temperature sensor faults.Replace the sensor; the system continues operating while ignoring the error.p. 19
28No blocking due to low temperature trend.Check for an iced evaporator, low refrigerant, or low evaporator fan speed.p. 19
CCPCold Climate Protection mode is active.Resets automatically.p. 18
chtCO2 condenser high temperature pre alarm.Resets automatically.p. 18
dFDefrost is in progress.Resets automatically.p. 18
dOrOpen door alarm.Resets automatically.p. 18
E0Regulation probe error.Resets automatically.p. 18
E1Second probe error.Resets automatically.p. 18
E2Door switch fault.Resets automatically.p. 18
E3Temperature mitigation algorithm is active.Resets automatically.p. 18
ECOECO mode is active.Resets automatically.p. 18
EEInternal parameters error.Reset is not possible.p. 18
EFOperating parameters error.Reset manually.p. 18
ErrRefrigerant system failure alarm.Resets automatically.p. 18
HIHigh temperature alarm.Resets automatically.p. 18
hPrCO2 high pressure pre alarm.Resets automatically.p. 18
LOLow temperature alarm.Resets automatically.p. 18
All Metalfrio error codes →

Metalfrio NG26CHC compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Metalfrio NG26CHCOther Commercial RefrigeratorSummit AL57GEdgeStar VBM101SS
Fridge adjustment range-40 °C to +70 °C (-40 °F to +158 °F)34 °F to 38 °F (1 °C, 3 °C)36 °F to 43 °F (2 °C, 6 °C)34 °F to 64 °F (1 °C, 18 °C)
Clearance at the sides6 in2" (5.1 cm)5 inches (127mm) (12.7 cm)1/2”
Clearance behind15 cm (5.9 in)2" (5.1 cm)5 inches (127mm) (12.7 cm)3/4”

Similar Metalfrio commercial refrigeration

Metalfrio NG10CHCModel family NG10CHCUser Manual21 pages