Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge adjustment range | -2 °C to 8 °C (28 °F, 46 °F)DA465Typical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 7 |
|---|---|---|
| Wait before use | approximately 12 hoursif the unit was not stored or moved upright | p. 4 |
| Clearance at the sides | 20cm (7 inches) (17.8 cm) needs more space than mostbetween the unit and walls or other objects, for ventilationTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 4 |
| Defrost | automaticthe appliance runs a defrost cycle every six hours | p. 4 |
Polar DA462 questions
Answers taken from this manual. Each one links to the page it comes from.
Why is water leaking from my refrigerator?
- Blocked discharge outlet. Clear the discharge outlet.
- Obstructed water movement. Clear the appliance floor, if applicable.
- Damaged water container. Call a POLAR agent or qualified technician.
- Overflowing drip tray. Empty the drip tray, if applicable.
- Appliance is not level. Adjust the screw feet, if applicable.
Manual: page 6
How often should I defrost the appliance?
Defrost the appliance at least every 3 months, or more often if required.
Manual: page 5
How much clearance does the unit need for ventilation?
20cm (7 inches) between the unit and walls or other objects; do not place it next to or near a heat source.
Other brands: Other 100 mm (4”) (3.9 in) · Summit 5” (127mm) · True 1" (25.4 mm) Compare all
Manual: page 4
How long should the unit stand upright before operation?
Approximately 12 hours, if it was not stored or moved upright.
Other brands: Other 24 hours · Summit about 2 hours · True 24 hours Compare all
Manual: page 4
How do I clean the door seal?
- Wash the door seal with warm, soapy water.
- Wipe the seal dry after cleaning.
Manual: page 5
The door is not sealing properly. What should I check?
Check that the door is shut and the seal is not damaged.
Manual: page 6
How do I start a manual defrost cycle?
- Hold the aux defrost button for 2 seconds.
- Confirm that the defrost light illuminates.
Manual: page 4
The temperature is too high or low. Could ice buildup be the cause?
- Ice buildup on the evaporator. Defrost the appliance.
- Dust blocking the condenser. Clean the condenser.
- Doors not shut properly. Check the doors and seals.
Manual: page 6
Polar DA462 compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Polar DA462 | Other Commercial Refrigerator | Summit FF64BCSS | Whynter CBM-815WS | |
|---|---|---|---|---|
| Fridge adjustment range | -2 °C to 8 °C (28 °F, 46 °F) | 34 °F to 38 °F (1 °C, 3 °C) | 36 °F to 43 °F (2 °C, 6 °C) | 34 °F - 43 °F / 1 °C - 6 °C |
| Wait before use | about 12 hours | at least 24 hours | about 2 hours | about 4 hours |
| Clearance at the sides | 20cm (7 inches) (17.8 cm) | 2" (5.1 cm) | 5” (127mm) | at least 5 inches (127mm) (12.7 cm) |
Similar Polar commercial refrigeration
| Polar DA546 | Instruction Manual | 48 pages |
|---|---|---|
| Polar CB507 | Instruction Manual | 48 pages |
| Polar DB319 | Instruction Manual | 40 pages |
| Polar DM075 | User Manual | 10 pages |
| Polar CB507 | Instruction Manual | 8 pages |
| Polar DB109-A | Instruction Manual | 8 pages |
| Polar GL180 | User Manual | 56 pages |
| POLAR-PAK® Drop-In Refrigeration System | Operating Instructions | 50 pages |