Randell error codes

10 Randell error and alarm codes from 3 manuals: what each code means and what the manual says to do.

10 codes3 manuals

Codes and what they mean

As described in each manual. The same code can mean different things on different models, so check the model column.

CodeMeaningWhat to doManual
CONCondenser temperature exceeds the high limit.Clean the condenser coil, remove airflow obstructions, and contact service.MNL2502, MNL2503
CONCondenser temperature high limit.Clean and inspect the condenser coil for airflow obstructions; contact service.9000W-290
E01S1 sensor failure.Contact service.MNL2502, MNL2503, 9000W-290
E02S2 sensor failure.Contact service.MNL2502, MNL2503, 9000W-290
E03S3 sensor failure.Contact service.MNL2502, MNL2503, 9000W-290
E04S4 sensor failure.Contact service.MNL2502, MNL2503, 9000W-290
HiHigh temperature alarm.Inspect door and drawer sealing.MNL2502, MNL2503, 9000W-290
LEACompressor has run continuously.Contact service.MNL2502, MNL2503
LEAContinuous compressor runtime.Contact service; inspect door sealing and condenser coil, cleaning if necessary.9000W-290
LoLow temperature alarm.Contact service.MNL2502, MNL2503, 9000W-290
uHiLine voltage is too high.Have a qualified technician verify the power source voltage; contact service.MNL2502, MNL2503
uHiLine voltage too high.Have a qualified technician verify the power source voltage; contact service.9000W-290
uLiLine voltage is too low.Have a qualified technician verify the power source voltage.MNL2502, MNL2503
uLiLine voltage too low.Have a qualified technician verify the power source voltage.9000W-290