Randell error codes
10 Randell error and alarm codes from 3 manuals: what each code means and what the manual says to do.
10 codes3 manuals
Codes and what they mean
As described in each manual. The same code can mean different things on different models, so check the model column.
| Code | Meaning | What to do | Manual |
|---|---|---|---|
| CON | Condenser temperature exceeds the high limit. | Clean the condenser coil, remove airflow obstructions, and contact service. | MNL2502, MNL2503 |
| CON | Condenser temperature high limit. | Clean and inspect the condenser coil for airflow obstructions; contact service. | 9000W-290 |
| E01 | S1 sensor failure. | Contact service. | MNL2502, MNL2503, 9000W-290 |
| E02 | S2 sensor failure. | Contact service. | MNL2502, MNL2503, 9000W-290 |
| E03 | S3 sensor failure. | Contact service. | MNL2502, MNL2503, 9000W-290 |
| E04 | S4 sensor failure. | Contact service. | MNL2502, MNL2503, 9000W-290 |
| Hi | High temperature alarm. | Inspect door and drawer sealing. | MNL2502, MNL2503, 9000W-290 |
| LEA | Compressor has run continuously. | Contact service. | MNL2502, MNL2503 |
| LEA | Continuous compressor runtime. | Contact service; inspect door sealing and condenser coil, cleaning if necessary. | 9000W-290 |
| Lo | Low temperature alarm. | Contact service. | MNL2502, MNL2503, 9000W-290 |
| uHi | Line voltage is too high. | Have a qualified technician verify the power source voltage; contact service. | MNL2502, MNL2503 |
| uHi | Line voltage too high. | Have a qualified technician verify the power source voltage; contact service. | 9000W-290 |
| uLi | Line voltage is too low. | Have a qualified technician verify the power source voltage. | MNL2502, MNL2503 |
| uLi | Line voltage too low. | Have a qualified technician verify the power source voltage. | 9000W-290 |