Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Time to cool down | approximately 45 minutes faster than mostbefore putting food in the rail2 hoursfor the base to cool to storage temperature before loading productTypical for commercial refrigeration: 1 to 24 hours | p. 2 |
|---|---|---|
| Clearance above | 0 inches (0 cm)Unit topTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 2 |
| Clearance at the sides | 0 inches (0 cm)Each side of unitTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 2 |
| Clearance behind | 0 inches (0 cm) needs less space than mostUnit rearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 2 |
| Defrost | manualWhen ice forms on the coil | p. 4 |
| Room temperature range | 70 °F (21 °C) - 86 °F (32 °C)Normal operating temperaturesTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C) | p. 3 |
Randell MNL2503 questions
Answers taken from this manual. Each one links to the page it comes from.
How do I drain water from the rail?
- Open the hinged mechanical compartment door.
- Place a container under the drain valve.
- Open the valve until all water has drained.
- Close the valve.
- Discard the water.
Manual: page 4
How do I clear ice from the coil?
How much clearance does the unit need around it?
0 inches is specified at the top, rear, and each side.
| Location | Clearance |
|---|---|
| Top | 0 inches |
| Rear | 0 inches |
| Each side | 0 inches |
Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all
Manual: page 2
How do I drain water after defrosting the rail?
- Open the hinged mechanical compartment door.
- Place a container under the drain valve.
- Open the valve until all water has drained.
- Close the valve.
- Discard the water.
Manual: page 4
What do the Danfoss controller codes mean?
These Danfoss displays identify temperature, condenser, voltage, runtime, and sensor conditions.
| Displayed code | Meaning |
|---|---|
| Hi, Lo | High or low temperature alarm |
| CON | Condenser temperature high limit |
| uHi, uLi | Line voltage too high or low |
| LEA | Continuous compressor runtime |
| E01 to E04 | S1 to S4 sensor failure |
Manual: page 6
How do I level the unit before use?
- Place the unit on a level, vibration-free floor.
- Adjust bullet feet or shim casters until all legs or casters contact the floor.
- Check that the work surface remains level.
Manual: page 2
How do I clean the condenser coils?
- Clean condenser coils monthly.
- Apply coil cleaner, or use a vacuum cleaner and brush.
- Brush in the fin direction, normally vertically, to avoid restricting airflow.
Manual: page 5
Why does the unit not run?
- No power reaches the unit. Plug in the unit.
- The control is off. Turn the controller on.
- The control is faulty. Call service at 888-9947636.
Manual: page 5
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| CON | Condenser temperature exceeds the high limit. | Inspect the coil for airflow obstructions; contact service. | p. 6 |
| E01 | S1 sensor failure. | Contact service. | p. 6 |
| E02 | S2 sensor failure. | Contact service. | p. 6 |
| E03 | S3 sensor failure. | Contact service. | p. 6 |
| E04 | S4 sensor failure. | Contact service. | p. 6 |
| Hi | High temperature alarm. | Inspect door or drawer sealing; contact service. | p. 6 |
| LEA | Compressor has run continuously. | Inspect door or drawer sealing; inspect and clean the condenser coil; contact service. | p. 6 |
| Lo | Low temperature alarm. | Clean the condenser coil; contact service. | p. 6 |
| uHi | Line voltage is too high. | Have a qualified technician verify power-source voltage; contact service. | p. 6 |
| uLi | Line voltage is too low. | Have a qualified technician verify power-source voltage. | p. 6 |
Randell MNL2503 compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Randell MNL2503 | True TUC-27F-HC | EdgeStar VBM101SS | Other Commercial Refrigerator | |
|---|---|---|---|---|
| Time to cool down | about 45 minutes | 24 hours | at least 24 hours | · |
| Clearance above | 0 inches (0 cm) | 0" (0 mm) | 1/2” | 12" (30.5 cm) |
| Clearance at the sides | 0 inches (0 cm) | 0" (0 mm) | 1/2” | 2" (5.1 cm) |
| Clearance behind | 0 inches (0 cm) | 0" (0 mm) | 3/4” | 2" (5.1 cm) |
| Room temperature range | 70 °F (21 °C) - 86 °F (32 °C) | 60 °F (15.5 °C) to 104 °F (40 °C) | 50 °F to 90 °F (10 °C, 32 °C) | below 90 °F (32 °C) |