Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Time to cool downapproximately 45 minutes faster than mostbefore putting food in the rail2 hoursfor the base to cool to storage temperature before loading productTypical for commercial refrigeration: 1 to 24 hoursp. 2
Clearance above0 inches (0 cm)Unit topTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 2
Clearance at the sides0 inches (0 cm)Each side of unitTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 2
Clearance behind0 inches (0 cm) needs less space than mostUnit rearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 2
DefrostmanualWhen ice forms on the coilp. 4
Room temperature range70 °F (21 °C) - 86 °F (32 °C)Normal operating temperaturesTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 3

Randell MNL2503 questions

Answers taken from this manual. Each one links to the page it comes from.

How do I drain water from the rail?
  1. Open the hinged mechanical compartment door.
  2. Place a container under the drain valve.
  3. Open the valve until all water has drained.
  4. Close the valve.
  5. Discard the water.

Manual: page 4

How do I clear ice from the coil?

Press and hold Defrost to start manual defrost when ice is on the coil.

Manual: page 4, page 5

How much clearance does the unit need around it?

0 inches is specified at the top, rear, and each side.

LocationClearance
Top0 inches
Rear0 inches
Each side0 inches

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all

Manual: page 2

How do I drain water after defrosting the rail?
  1. Open the hinged mechanical compartment door.
  2. Place a container under the drain valve.
  3. Open the valve until all water has drained.
  4. Close the valve.
  5. Discard the water.

Manual: page 4

What do the Danfoss controller codes mean?

These Danfoss displays identify temperature, condenser, voltage, runtime, and sensor conditions.

Displayed codeMeaning
Hi, LoHigh or low temperature alarm
CONCondenser temperature high limit
uHi, uLiLine voltage too high or low
LEAContinuous compressor runtime
E01 to E04S1 to S4 sensor failure

Manual: page 6

How do I level the unit before use?
  1. Place the unit on a level, vibration-free floor.
  2. Adjust bullet feet or shim casters until all legs or casters contact the floor.
  3. Check that the work surface remains level.

Manual: page 2

How do I clean the condenser coils?
  1. Clean condenser coils monthly.
  2. Apply coil cleaner, or use a vacuum cleaner and brush.
  3. Brush in the fin direction, normally vertically, to avoid restricting airflow.

Manual: page 5

Why does the unit not run?
  • No power reaches the unit. Plug in the unit.
  • The control is off. Turn the controller on.
  • The control is faulty. Call service at 888-9947636.

Manual: page 5

Error codes in this manual

CodeMeaningWhat to do
CONCondenser temperature exceeds the high limit.Inspect the coil for airflow obstructions; contact service.p. 6
E01S1 sensor failure.Contact service.p. 6
E02S2 sensor failure.Contact service.p. 6
E03S3 sensor failure.Contact service.p. 6
E04S4 sensor failure.Contact service.p. 6
HiHigh temperature alarm.Inspect door or drawer sealing; contact service.p. 6
LEACompressor has run continuously.Inspect door or drawer sealing; inspect and clean the condenser coil; contact service.p. 6
LoLow temperature alarm.Clean the condenser coil; contact service.p. 6
uHiLine voltage is too high.Have a qualified technician verify power-source voltage; contact service.p. 6
uLiLine voltage is too low.Have a qualified technician verify power-source voltage.p. 6
All Randell error codes →

Randell MNL2503 compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Randell MNL2503True TUC-27F-HCEdgeStar VBM101SSOther Commercial Refrigerator
Time to cool downabout 45 minutes24 hoursat least 24 hours·
Clearance above0 inches (0 cm)0" (0 mm)1/2”12" (30.5 cm)
Clearance at the sides0 inches (0 cm)0" (0 mm)1/2”2" (5.1 cm)
Clearance behind0 inches (0 cm)0" (0 mm)3/4”2" (5.1 cm)
Room temperature range70 °F (21 °C) - 86 °F (32 °C)60 °F (15.5 °C) to 104 °F (40 °C)50 °F to 90 °F (10 °C, 32 °C)below 90 °F (32 °C)