Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting38-40 °F (3.3-4.4 °C)refrigerated bakeryTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 11
Time to cool downseveral hoursafter startup, before changing the control settingTypical for commercial refrigeration: 1 to 24 hoursp. 11
Defrostoff-cycle defrostTCGR modelp. 12

True TCGR-50-CD questions

Answers taken from this manual. Each one links to the page it comes from.

What setting should I use on the mechanical temperature control?

Set the control to #4 or #5; #1 is warmest, #9 is coldest, and #0 is off.

Manual: page 12

Why does the displayed temperature move up and down?

The display shows cabinet temperature, not product temperature, and refrigeration cycles can make its reading move up and down. Check product temperature for the most accurate operating reading.

Manual: page 12

Do I need to manually defrost the True TCGR case?

No. The TCGR performs off-cycle defrost automatically, stopping the compressor without heaters until the evaporator coil warms, then restarting it.

Manual: page 12

How do I level the True TCGR-50-CD display case?

For a non-mobile model, accurate leveling supports condensate removal, door operation, and front glass door sealing.

  1. Place the unit in its final location.
  2. Set a level on the interior floor; check front-to-back, side-to-side, and all four sides.
  3. If uneven, take weight off each leg leveler, then adjust it by hand or wrench.
  4. Repeat for every leg leveler until the cabinet is level in all directions.
  5. Check that the drain hose or hoses rest in the pan.
  6. For a center leveling screw, castor, or leg, adjust it for full floor contact.

Manual: page 6

What should I do if the refrigerator arrives with freight damage?

Inspect the unit before installation and immediately file a claim with the delivery freight carrier if damage appears.

Manual: page 4

Can I use an extension cord with this refrigerator?

No. Do not use an extension cord; True will not warranty a refrigerator connected to one.

Manual: page 3

Similar True commercial refrigeration

True TCGG-36-S-LDModel family TCGOwner's Manual18 pages
True TCR-1-2-CL-SSI-3D-3DInstallation Manual21 pages