Have a question about the True TG1R-1S-HC? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 35 °F (2 °C)Refrigerators with the temperature control set at No. 4 positionTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 13 |
|---|---|---|
| Time to cool down | several hoursAfter plugging in, before changing the control settingTypical for commercial refrigeration: 1 to 24 hours | p. 13 |
True TG1R-1S-HC questions
Answers taken from this manual. Each one links to the page it comes from.
What temperature does the No. 4 control setting provide?
Approximately 35 °F at No. 4.
Manual: page 13
How long should I wait before changing the temperature control?
Several hours, until the cabinet has cooled completely.
Manual: page 13
What defrost schedule does True recommend?
Use 30-minute defrost cycles three times daily, scheduled at 6:00 a.m., 2:00 p.m., and 10:00 p.m.
Manual: page 20
How do I level the refrigerator on castors?
- Place leveling shims between the rail end and bearing race.
- Install the needed shims with each slot touching the castor’s threaded stem.
- Turn the bearing race counter-clockwise until level front to back and side to side.
- If using multiple shims, turn their slots 90° so they are not aligned.
- Turn the bearing race clockwise, then tighten the anchoring bolt with a 3/4 inch wrench.
Manual: page 10
How do I remove the interior light cover?
Disconnect power to the cabinet before working on the light.
- Squeeze the plastic lampshield together.
- Pull the lampshield down.
Manual: page 24
How do I remove a bulb from integrated door lighting?
Disconnect power to the cabinet before removing the bulb.
- Squeeze the plastic lampshield together and pull it away from the door.
- Push the bulb down while pulling the spring-activated lampholder up.
- Remove the bulb through the clearance created by the lampholder.
Manual: page 24
Similar True commercial refrigeration
| True TGO-27-POP01 | Installation Manual | 47 pages |
|---|---|---|
| True TGO-27-POP01 | Service Manual | 44 pages |
| True TGN-1R-1S | Installation Manual | 32 pages |
| True TSCI-150PR-SWG-R | Installation Manual | 68 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True TBR32-RISZ1-L-B-S-1 | Installation Manual | 56 pages |
| True TBR32-RISZ1-L-B-S-1 | Service Manual | 56 pages |