Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Freezer factory setting0oF.All models as shippedTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C)p. 6
Wait before use3 hoursIf the unit is tipped onto its backp. 8
Clearance above0 in. (0 cm)At the topTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 7
Clearance at the sides0.0 in. (0 cm)At the right sideTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 7
Clearance behind1.0 in. (2.5 cm)At the rearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 7

Beverage-Air WTFCS questions

Answers taken from this manual. Each one links to the page it comes from.

What minimum clearance does the freezer need around it?

Minimum clearances are listed below, including the required space below the cabinet.

LocationMinimum clearance
Top0 in.
Rear1.0 in.
Left side0.0 in.
Right side0.0 in.
Below3-3/4 in.

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all

Manual: page 7

How long should I wait before starting the freezer after tipping it onto its back?

Wait 3 hours before starting the unit.

Other brands: Other 24 hours · Summit about 2 hours · True 24 hours Compare all

Manual: page 8

What does dEF mean on the freezer display?

dEF means the unit is defrosting, which is normal operation and requires no action.

Manual: page 10

How do I start a manual defrost?

Quickly press and release DEFROST (ESC) to activate manual defrost.

Manual: page 13

How do I start the freezer after connecting power?
  1. Connect the cord to its dedicated, correct power supply, not a GFI or GFCI outlet.
  2. The unit should soon blow warm air from the top and cool air from the inside blower.
  3. Leave it powered on until it reaches the desired set point before loading product.

Manual: page 9, page 10

What is the freezer’s factory temperature setting?

0º F is the factory temperature setting.

Manual: page 9, page 10

How do I silence an alarm?

Press any button to silence the alarm; its alarm icon keeps flashing.

Manual: page 15

Beverage-Air WTFCS compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Beverage-Air WTFCSOther Commercial RefrigeratorGram Commercial RefrigeratorVictory CBF
Freezer factory setting0oF-7°Fto -1 °F (-22 °C, -18 °C)-18 °C (0 °F)0 °F (-18 °C)
Wait before use3 hoursat least 24 hoursat least 2 hours3 hours
Clearance above0 in12" (30.5 cm)250 mm (9.8 in)0 in
Clearance at the sides0.0 in2" (5.1 cm)20 mm (0.8 in)0.0 in. left; 0.0 in. right (0 cm, 0 cm)
Clearance behind1.0 in2" (5.1 cm)max. 75 mm (3 in)1.0 in

Similar Beverage-Air commercial refrigeration

Beverage-Air WTF*36AHC*********Model family WTFInstallation & Operation Manual26 pages
Beverage-Air WTR*41AHC*********Installation & Operation Manual32 pages
Beverage-Air BF200RB-PFO-XLOperating Instructions74 pages
Beverage-Air MT08-1[#]User Manual69 pages
Beverage-Air PR3HC-1A*S******Installation & Operation Manual54 pages
Beverage-Air BB58HC****G*******Installation & Operation Manual46 pages
Beverage-Air DD58HC****G*******Installation & Operation Manual39 pages
Beverage-Air 3071629RV05Operating Instructions39 pages
All Beverage-Air commercial refrigeration →