Gram Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What are the storage-program temperature settings?

The storage-program setpoint is model-specific.

ModelSetpoint
SF 550-18ºC
KP 60/82+4ºC

Manual: page 15

How do I maintain the refrigerator door gasket?

Clean the gasket regularly with a mild soap solution and inspect its condition. A worn gasket can reduce cabinet tightness, causing humidity, internal ice, or reduced refrigeration capacity.

Manual: page 26

What should I do if the door gasket needs replacement?

Contact your supplier for a replacement gasket.

Manual: page 26

Why does defrosting start when I turn on a cold unit?

A cold unit begins with a defrosting cycle when started in a cold room; the display shows the internal temperature and the defrosting symbol lights.

Manual: page 14

Can I speed up defrosting with a sharp object?

No. Do not use pointed or sharp objects to speed up defrosting.

Manual: page 14

What happens after a power failure?

The control restores the product when power returns, usually retaining the temperature setting; a prolonged outage may restore the factory setting.

Manual: page 25

Can I use this product to chill or freeze foodstuff?

No. It is for storing foodstuff at a constant temperature, not for chilling or freezing foodstuff.

Manual: page 4

Who should carry out maintenance or repairs?

Gram Commercial technicians or Gram-approved technicians should carry out common maintenance and eventual repairs.

Manual: page 4

Error codes in this manual

CodeMeaningWhat to do
A1The door alarm was activated.Close the door, then press the button to delete the alarm.p. 21
A2The local maximum temperature alarm was activated.Wait until temperature is below the maximum, then press the button.p. 21
dAThe door alarm was activated.Close the door.p. 21
F1The room temperature sensor is defective.Have the service department replace the sensor.p. 21
F2The evaporator sensor is defective or the evaporator is heavily iced.Defrost completely for 24 hours; contact service if the fault remains.p. 21
F3The condensation sensor has a problem.Have the sensor replaced as soon as possible.p. 22
F4The second condensation sensor has failed.Follow the F3 fault procedure and have the sensor replaced.p. 22
F5The PCL hard chill temperature sensor has failed.Contact the service department to replace the sensor.p. 22
F7The condenser is overheating or undercooling.p. 22
FILTERThe condenser air filter needs cleaning.Clean the filter, then reset the controller using the specified key combination.p. 23
OPThe door is open.Close the door.p. 21
All Gram error codes →

Similar Gram commercial refrigeration

Gram Commercial Refrigeration Instruction ManualInstruction Manual154 pages
Gram Commercial Refrigeration User ManualUser Manual140 pages
Gram IO-REF-1455Instruction Manual132 pages
Gram Commercial Refrigeration Instruction ManualInstruction Manual131 pages
Gram COMPACT 600 Gram RefrigeratorUser Manual124 pages
Gram IO-REF-1453Instruction Manual124 pages
Gram IO-REF-1421Instruction Manual120 pages
Gram IO-REF-1419Operating Instructions120 pages
All Gram commercial refrigeration →