Same manual for other models

These manuals share their text with this one.

Gram Commercial RefrigeratorCommercial RefrigeratorSame manualUser Manual · 19 pages
Gram Commercial RefrigeratorCommercial RefrigeratorShares large sectionsUser Manual · 124 pages

Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Room temperature range+16 °C to +30 °C (61 °F, 86 °F)Operating ambient temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 31

Gram Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What room temperature can this cabinet operate in?

+16 °C to +30 °C.

Manual: page 31

How long should I wait before restarting the cabinet?

Allow a minimum of 3 minutes after shutdown before restarting the cabinet.

Manual: page 34

What is the maximum load for a wire shelf?

40 kg is the maximum load for a wire shelf.

Manual: page 34

What should I do if the cabinet develops a problem?

Contact your local dealer; Gram representatives and dealers are available to help with product problems.

Manual: page 27

How do I connect the cabinet to power?
  1. Connect the supplied power cord to the main supply inlet at the cabinet’s back.
  2. Use alternating current matching the voltage and frequency shown on the name plate.
  3. Use only the supplied cord, without an extension cord.

Manual: page 33

What are the factory default temperature alarm settings?

These are the controller's factory defaults.

ParameterFactory default
**hAL High Alarm Limit+ 25 °C
**LAL Low Alarm Limit- 29 °C
**dAh Time delay Alarm high120 minutes
**dAL Time delay Alarm Low20 minutes
**Atd Alarm temperature differential2K

Manual: page 37

How many temperature alarms can the log store?

10 temperature alarms are stored, with the oldest erased when a new one occurs.

Manual: page 37

How do I clean and maintain this cabinet?

Use these cleaning steps before returning the cabinet to operation.

  1. Vacuum the compressor compartment and condenser with a brush.
  2. Wash the exterior with a hot, soapy, damp cloth.
  3. Rinse with a water-only moist cloth, then dry the cabinet.
  4. Finish stainless steel exteriors with stainless steel polish.
  5. Clean the inside and door gasket regularly with mild soap solution.
  6. Check the cabinet thoroughly before putting it back into operation.

Manual: page 41

The cabinet is not refrigerating. What should I check?
  • Power is disconnected, switched off, or a fuse has blown. Check the socket, switch, and fuse.
  • The cause is not found. Contact your dealer and provide the cabinet type and 8-digit serial number.

Manual: page 41

Error codes in this manual

CodeMeaningWhat to do
A0Current or ongoing temperature alarm.A current alarm cannot be reset or deleted.p. 38
AhHigh temperature alarm.Review and acknowledge the alarm to reset its symbol.p. 38
ALLow temperature alarm.Review and acknowledge the alarm to reset its symbol.p. 38
E1Defective room temperature sensor.Monitor the temperature and request service immediately.p. 38
E2Defective evaporator sensor.Expect time-based defrosting and request service assistance.p. 38
OPDoor is open, or has been open over two minutes.Close the door.p. 38
All Gram error codes →

Similar Gram commercial refrigeration

Gram Commercial Refrigeration Instruction ManualInstruction Manual154 pages
Gram Commercial Refrigeration User ManualUser Manual140 pages
Gram IO-REF-1455Instruction Manual132 pages
Gram Commercial Refrigeration Instruction ManualInstruction Manual131 pages
Gram IO-REF-1453Instruction Manual124 pages
Gram IO-REF-1421Instruction Manual120 pages
Gram IO-REF-1419Operating Instructions120 pages
Gram 6C1854Operating Instructions120 pages
All Gram commercial refrigeration →