Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before useat least 2 hoursif transported in a horizontal positionp. 7
Defrostautomatically 4 times per daynormal defrostingp. 20
Room temperature range+16C and +40 °C (104 °F)operating room temperatureTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 7

Gram Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I clean the defrost-water tray?
  1. Switch off electrical power to the product.
  2. Wear gloves because the rear re-evaporation components may be hot.
  3. Clean the re-evaporation tray as needed, at least once annually.
  4. Avoid damaging the tube, heating element, or associated float switch.

Manual: page 21

What does the defrost indicator mean?

A lit defrost indicator means the controls are defrosting; a flashing indicator means drip time follows or defrosting was blocked.

Manual: page 13

How do I start manual defrosting?

Press the defrosting button to initiate manual defrosting.

Manual: page 14

How long should I wait before starting the cabinet after horizontal transport?

Wait at least 2 hours before starting it after horizontal transport.

Manual: page 7

Can I use this appliance to chill or freeze food?

No. It is intended for food storage at a constant temperature, not chilling or freezing.

Manual: page 4

How long should I wait before turning the product on again?

Minimum 3 minutes protects the compressor when restarting the product.

Manual: page 11

Can I use an extension cord with this product?

No. Use only the supplied cord; if the wall socket is too far away, contact an electrician to establish one within cord range.

Manual: page 10

Gram Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Gram Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSSWhynter CBM-815WS
Wait before useat least 2 hoursat least 24 hoursabout 2 hoursabout 4 hours
Defrostautomatically 4 times per day·automatic·
Room temperature range+16C and +40 °C (104 °F)below 90 °F (32 °C)above 44 °F (7 °C) and below 90 °F (32 °C)72º- 78ºF / 23º26ºC

Similar Gram commercial refrigeration

Gram Commercial Refrigeration Instruction ManualInstruction Manual154 pages
Gram Commercial Refrigeration User ManualUser Manual140 pages
Gram IO-REF-1455Instruction Manual132 pages
Gram Commercial Refrigeration Instruction ManualInstruction Manual131 pages
Gram COMPACT 600 Gram RefrigeratorUser Manual124 pages
Gram IO-REF-1453Instruction Manual124 pages
Gram IO-REF-1421Instruction Manual120 pages
Gram IO-REF-1419Operating Instructions120 pages
All Gram commercial refrigeration →