Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting35 °F (1.7 °C)refrigerators, factory settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 13
Freezer factory setting-10 °F (-23.3 °C) colder than mostfreezers, factory settingTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C)p. 13
Time to cool downseveral hoursbefore changing the control settingTypical for commercial refrigeration: 1 to 24 hoursp. 13
Door-open alarm after5 minutesdoor remains openTypical for commercial refrigeration: 1 to 5 minutesp. 14
Clearance behindone inchGDM refrigerator3 inches (7.6 cm)GDM freezerTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 9
DefrostautomaticThe control initiates defrost at programmed intervals.p. 15

True GDM-23-LD questions

Answers taken from this manual. Each one links to the page it comes from.

What are the factory temperature settings for True refrigerators and freezers?

The factory settings are approximate and apply to refrigerators and freezers as listed.

ApplianceFactory setting
Refrigerator35 °F (1.7 °C)
Freezer-10 °F (-23.3 °C)

Manual: page 13

What temperature does the electronic control display?

It displays cabinet temperature, not product temperature; verify the product temperature for the most accurate operating check.

Manual: page 15

How much space should I leave behind a GDM cabinet?

The required rear clearance depends on whether the cabinet is a refrigerator or freezer.

Cabinet typeRear clearance
GDM refrigeratorone inch
GDM freezer3 inches

Other brands: Other 4” · Summit 5” (127mm) · EdgeStar 3/4” Compare all

Manual: page 9

How long should I wait before restarting the unit?

Five minutes: wait before starting the unit again after it is disconnected or shut off.

Manual: page 13

How do I turn on the UPS battery backup?
  1. From the cabinet’s back, find the blue Notice sticker beside the power switch.
  2. Press and hold the power switch for 2 seconds, then release it.
  3. Confirm the power switch illuminates green while the UPS provides power.
  4. Let the cabinet run at least 8 hours to charge the UPS battery backup.

Manual: page 11

Does setting the temperature control to 0 turn off the lights?

No. The 0 position does not remove power from the light circuit.

Manual: page 3

How do I clean the condenser?
  1. Disconnect the unit from electrical power.
  2. Remove the louvered grill.
  3. Vacuum or brush debris from the finned condenser coil.
  4. For heavy buildup, use compressed air with eye protection.
  5. Replace the louvered grill.
  6. If dirt remains, contact a refrigeration service company.
  7. Reconnect electrical power to the unit.

Manual: page 19

True GDM-23-LD compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

True GDM-23-LDTurbo Air PRO-26-2RGram Commercial RefrigeratorHoshizaki Commercial Refrigerator
Fridge factory setting35 °F (1.7 °C)No. “5”5 °C (41 °F)36 °F (2 °C)
Freezer factory setting-10 °F (-23.3 °C)No. “5”-18 °C (0 °F)-3 °F (-19 °C)
Door-open alarm after5 minutesaround 30 secondsmore than 2 minutes3 minutes

Similar True commercial refrigeration

True GDM-05-HC-LDModel family GDM05HInstallation & Operation Manual40 pages
True GDM-05-HC-LDModel family GDM05HService Manual20 pages
True GDM-23-HST02-HCModel family GDM23Installation Manual48 pages
True GDM-23-HST02-HCModel family GDM23Installation Manual48 pages
True GDM-26-HCModel family GDM2Service Manual40 pages
True GDM-49-SCI-HCModel family GDMInstallation Manual56 pages
True GDM-49-SCI-HCModel family GDMInstallation Manual56 pages
True GDIM-26-NTInstallation Manual28 pages
All True commercial refrigeration →