Have a question about the Turbo Air TGM-10SD-N? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 37℉(3℃)ChillersTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 13 |
|---|---|---|
| Fridge adjustment range | From '50℉' to '30℉'('10℃' to '-1℃')RefrigeratorsTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 16 |
| Freezer factory setting | -8℉(-22℃)FreezersTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C) | p. 13 |
| Freezer adjustment range | From '5℉' to '-17℉'('-15℃' to '-27℃')FreezersTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 16 |
| Time to cool down | 24 hoursBefore usage after installationTypical for commercial refrigeration: 1 to 24 hours | p. 11 |
| Door-open alarm after | 30 seconds sooner than mostAny door remains openTypical for commercial refrigeration: 1 to 5 minutes | p. 17 |
| Clearance behind | 5 inches (12.7 cm) needs more space than mostTurbo Air recommendation from the wallTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 11 |
| Defrost | automaticThe defrost cycleautomatically controlled | p. 13 |
| Room temperature range | 50 °F (10 °C) to 100 °F (38 °C)Installation locationTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C) | p. 11 |
Turbo Air TGM-10SD-N questions
Answers taken from this manual. Each one links to the page it comes from.
What temperatures are set by default for chillers and freezers?
The default settings differ between chillers and freezers.
| Section | Default temperature |
|---|---|
| Chillers | 37℉(3℃) |
| Freezers | -8℉(-22℃) |
Manual: page 13
How do I change the temperature setting?
- For a higher temperature, press the temperature up(+) button.
- For a lower temperature, press the temperature down(-) button.
Manual: page 13
Why are there water droplets inside or outside the cabinet?
- Rainy-season humidity. Wipe moisture from the exterior with a dry cloth.
- Frequent door opening or damp food. Keep the door closed to clear interior moisture.
Manual: page 19
Is condensation around the door and cabinet front normal?
Yes. Moisture can form around the door edge and cabinet front during normal operation.
Manual: page 19
How does automatic defrosting work?
The electronic controller detects the defrost period and automatically removes evaporator ice while adjusting operation for energy-saving temperatures.
Manual: page 16
Why does the freezer display keep showing an earlier temperature during defrosting?
During the defrost cycle, the display shows the last measured temperature from before defrosting began.
Manual: page 18
How long should I run the refrigerator before using it?
Run it for 24 hours before use.
Other brands: Other 5-6 hours · True 24 hours · Fisher & Paykel 2 to 3 hours Compare all
Manual: page 11
How long should I wait before restarting after disconnection?
Wait 5 minutes before restarting after disconnection.
Manual: page 12
Turbo Air TGM-10SD-N compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Turbo Air TGM-10SD-N | Gram Commercial Refrigerator | Maxx Cold MCFT-23FDHC | Other Commercial Refrigerator | |
|---|---|---|---|---|
| Fridge factory setting | 37℉(3℃) | 5 °C (41 °F) | 35˚F(+2˚C) | 34 °F to 38 °F (1 °C, 3 °C) |
| Fridge adjustment range | From '50℉' to '30℉'('10℃' to '-1℃') | 2 to 12 °C (36 to 54 °F) | 39˚F to 28˚F(+4˚C to -2˚C) | 34 °F to 38 °F (1 °C, 3 °C) |
| Freezer factory setting | -8℉(-22℃) | -18 °C (0 °F) | 0˚F(-18˚C) | -7°Fto -1 °F (-22 °C, -18 °C) |
| Freezer adjustment range | From '5℉' to '-17℉'('-15℃' to '-27℃') | -10 to -22 °C (14 to -8 °F) | 5˚F to -9˚F(-15˚C to -23˚C) | -7°Fto -1 °F (-22 °C, -18 °C) |
| Time to cool down | 24 hours | · | · | · |
| Door-open alarm after | 30 seconds | more than 2 minutes | 3 minutes | · |
| Clearance behind | 5 inches (12.7 cm) | max. 75 mm (3 in) | 5 inch (12.7 cm) | 2" (5.1 cm) |
Similar Turbo Air commercial refrigeration
| Turbo Air TGF-49FModel family TGF49 | Service Manual | 128 pages |
|---|---|---|
| Turbo Air TGM-11RV-N6Model family TGM11 | Service Manual | 33 pages |
| Turbo Air TGM-11Model family TGM11 | User Manual | 24 pages |
| Turbo Air TGM-69RModel family TGM | Operating Instructions | 8 pages |
| Turbo Air TSF-23SD | Service Manual | 53 pages |
| Turbo Air TSF-23SD | Service Manual | 46 pages |
| Turbo Air TST-28SD | Service Manual | 34 pages |
| Turbo Air TBB-24-48S-N | User Manual | 28 pages |