Have a question about the True STM1R-1S? The AI assistant looks through this manual and shows the pages with the answer.
Related manuals
These manuals share their text with this one.
| True TCR-1-2-CL-SSI-3D-3DTCR-1-2-CL-SSI-3D-3D | Shares large sections | Installation Manual · 21 pages |
|---|---|---|
| True Commercial RefrigeratorCommercial Refrigerator | Shares large sections | Installation Manual · 20 pages |
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | approximately 35 °F (1.6 °C)refrigeratorsTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 12 |
|---|---|---|
| Freezer factory setting | approximately -10 °F (-23.3 °C) colder than mostFreezersTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C) | p. 12 |
| Time to cool down | several hoursafter startup, before changing the control settingTypical for commercial refrigeration: 1 to 24 hours | p. 12 |
| Clearance behind | 1 inch (2.5 cm)refrigerator, between the wall and rear of cabinetTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 7 |
True STM1R-1S questions
Answers taken from this manual. Each one links to the page it comes from.
What temperature is the refrigerator factory-set to?
Approximately 35 °F (1.6 °C).
Manual: page 12
Why does the displayed temperature differ from the temperature setting?
The Set-Point controls cycling, while the display reports cabinet temperature, which changes with the refrigeration cycle. Product temperature is the most accurate measure of operating temperature.
Manual: page 13
How much space should I leave behind the refrigerator?
Leave 1 inch between the wall and the refrigerator’s rear for ventilation.
Other brands: Other 4” · Summit 5” (127mm) · EdgeStar 3/4” Compare all
Manual: page 7
What does dEF mean on the display?
A programmed defrost cycle is underway. dEF appears while the compressor stops; freezers also stop evaporator fans and energize heaters, followed by a possible short restart delay.
Manual: page 13
Does OFF mean the cabinet has no power?
No. OFF deactivates the electrical components, but cabinet power remains; unplug the cabinet before repairs.
Manual: page 15
How do I restart the LAE control?
- The control may need to be unlocked first.
- Press and hold the Stand-by button until OFF appears, then release it.
- Repeat the prior steps until a temperature appears.
Manual: page 15
How do I level a non-mobile TRUE cooler?
- Set the cooler in its final location, leaving one inch behind refrigerators or 3 inches behind freezers.
- Place a level inside near the doors, parallel to the cabinet front.
- Place the level inside at the rear, parallel to the cabinet back.
- Check both sides, parallel to the cooler depth, and adjust until level.
- Adjust the center leveling screw, castor, or leg until it contacts the floor.
- Position the drain hose or hoses in the pan.
Manual: page 7
How do I level a castored unit on an uneven floor?
- Turn the bearing race counter-clockwise until the cabinet is level front to back and side to side.
- Install each shim between the rail end and bearing race, with its slot against the threaded stem.
- For multiple shims, turn each slot 90° so the slots are not aligned.
- Turn the bearing race clockwise, then tighten the anchoring bolt with a 3/4 inch open-end wrench.
- Raise the unit slowly to its upright position to avoid lower rail damage.
Manual: page 6
True STM1R-1S compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| True STM1R-1S | Other Commercial Refrigerator | Summit FF64BCSS | Turbo Air PRO-26-2R | |
|---|---|---|---|---|
| Fridge factory setting | about 35 °F (1.6 °C) | 34 °F to 38 °F (1 °C, 3 °C) | 38 °F/3 °C | No. “5” |
| Freezer factory setting | about -10 °F (-23.3 °C) | -7°Fto -1 °F (-22 °C, -18 °C) | 0 °F/-18 °C | No. “5” |
| Clearance behind | 1 inch (2.5 cm) | 2" (5.1 cm) | 5” (127mm) | 5 inches (12.7 cm) |
Similar True commercial refrigeration
| True STR1RRI89-1S | Installation Manual | 36 pages |
|---|---|---|
| True STA1DT-2HS-HC | Installation & Operation Manual | 24 pages |
| True Commercial Refrigeration Installation Manual | Installation Manual | 300 pages |
| True Commercial Refrigeration Installation Manual | Installation Manual | 240 pages |
| True TSCI-150PR-SWG-R | Installation Manual | 68 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True TBR32-RISZ1-L-B-S-1 | Installation Manual | 56 pages |