Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before usetwice the time it has been laying down (up to four (4) hours)Appliance laid on its back or side24 hoursTime laying down exceeds four (4) hoursp. 11
Clearance above12" Open (304.8 mm)Spec Series applianceTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 9
Clearance at the sides0" (0 mm)Spec Series applianceTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 9
Clearance behind1" (25.4 mm)Spec Series applianceTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 9

True STR1RRI89-1S questions

Answers taken from this manual. Each one links to the page it comes from.

What do the temperature-control knob positions mean?
  • #9 is the coldest position.
  • #1 is the warmest position.
  • #0 or Off turns the compressor off.

Manual: page 20

What does dEF mean on the display?

dEF means the appliance is in defrost mode. After defrost, the display can briefly delay showing the temperature and may also show dEF during refrigeration.

Manual: page 21

What clearances does the Spec Series appliance need?

The required ventilation clearances are listed below.

LocationRequired clearance
Top12" Open (304.8 mm)
Sides0" (0 mm)
Back1" (25.4 mm)

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · EdgeStar 1/2” Compare all

Manual: page 9

How do I adjust the door sweeper gasket if the door binds?
  1. Loosen the slotted thumbscrews.
  2. Adjust the gasket up, down, or side to side.
  3. Set the sweeper gasket to make some contact with the ramp when the door closes.
  4. Open the door 3-4” (76.2 to 101.6 mm) and let it close; readjust as needed.
  5. Tighten the slotted thumbscrews.

Manual: page 16

How is defrosting handled?

Defrosting starts through the temperature control or a timer; models TDC, TFM, THDC, and TMW require manual defrosting.

Manual: page 21

How long must the unit stand upright before I plug it in?
  • Leave it upright for twice the time it was on its side or back, up to four (4) hours.
  • Wait 24 hours upright if the appliance was on its side or back longer than four (4) hours.

Other brands: Other 24 hours · Summit about 2 hours · Whynter about 4 hours Compare all

Manual: page 11

How do I connect and disconnect the power cord?
  1. Use the correct outlet for the appliance.
  2. Do not use an extension cord or adapter plug.
  3. Fully seat the power cord in the appliance receptacle until it locks.
  4. To remove it, depress the red button.

Manual: page 10

How do I level this refrigerator for proper door operation?

Level it in its final position, front-to-back and side-to-side, because leveling affects door operation.

  1. Place a level inside near the doors, parallel to the front, and level the appliance.
  2. Place the level inside at the rear, parallel to the back, and level the appliance.
  3. Place the level on each side’s inside floor, parallel to the sides, and level the appliance.

Manual: page 14

What should I do if the door binds on the ramp?

Loosen the slotted thumbscrews and adjust the door sweeper gasket.

  1. Move the gasket up, down, or side to side.
  2. Leave some gasket contact with the ramp when the door closes.
  3. Open the door 3-4” (76.2-101.6 mm) and let it close.
  4. Readjust the gasket as needed, then tighten the slotted thumbscrews.

Manual: page 16

True STR1RRI89-1S compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

True STR1RRI89-1SOther Commercial RefrigeratorSummit FF64BCSSEdgeStar VBM101SS
Clearance above12" Open (304.8 mm)12" (30.5 cm)4“(102mm)1/2”
Clearance at the sides0" (0 mm)2" (5.1 cm)5” (127mm)1/2”
Clearance behind1" (25.4 mm)2" (5.1 cm)5” (127mm)3/4”

Similar True commercial refrigeration

True STM1R-1SInstallation Manual26 pages
True STA1DT-2HS-HCInstallation & Operation Manual24 pages
True Commercial Refrigeration Installation ManualInstallation Manual300 pages
True Commercial Refrigeration Installation ManualInstallation Manual240 pages
True TSCI-150PR-SWG-RInstallation Manual68 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True TBR32-RISZ1-L-B-S-1Installation Manual56 pages
All True commercial refrigeration →