Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Wait before use | 24 hoursBefore plugging the cabinet into a power source | p. 5 |
|---|---|---|
| Clearance above | 12" Open (304.8 mm)STR, STA, STGTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 4 |
| Clearance at the sides | 0" (0 cm)STR, STA, STGTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 4 |
| Clearance behind | 1" (25.4 mm)STR, STA, STG3" (73 mm)Space between the wall and the rear of the cabinet for ventilation.Typical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 4 p. 7 |
True STA1DT-2HS-HC questions
Answers taken from this manual. Each one links to the page it comes from.
Why does the temperature display rise and fall?
Temperature displays can rise and fall during refrigeration and defrost because they reflect air or evaporator conditions, not product temperature. Check product temperature for the most accurate operating result.
Manual: page 17
How long should I run the cooler before loading product?
Run the unit empty for 24 hours before loading product to verify proper operation.
Manual: page 16
What clearances does the cabinet require?
For STR, STA, and STG units, use these cabinet clearances.
| Location | Required clearance |
|---|---|
| Top | 12" Open (304.8 mm) |
| Sides | 0" |
| Back | 1" (25.4 mm) |
Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · EdgeStar 1/2” Compare all
Manual: page 4
How much clearance do adjustable legs provide underneath?
Adjustable legs provide 6" (152 mm) of clearance under the cabinet.
Manual: page 6
How does this refrigerator defrost?
Automatic defrost is initiated by a defrost timer or electronic control; refrigerator evaporator fans clear the coil during defrost.
Manual: page 17
What does def mean on the display?
def means defrost is occurring; the display may continue showing it briefly after defrost ends.
Manual: page 17
What spacing do the tray-slide pilasters require?
Use these measurements when positioning the tray-slide pilasters.
| Measurement | Required spacing |
|---|---|
| Front-to-back center holes | 24-5/8” (625mm) |
| Angle and rod trays | 18-1/8” (460 mm) |
| Universal trays | 21-1/4” (540 mm) |
Manual: page 10
True STA1DT-2HS-HC compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| True STA1DT-2HS-HC | Other Commercial Refrigerator | Summit AL57G | Gram Commercial Refrigerator | |
|---|---|---|---|---|
| Wait before use | 24 hours | at least 24 hours | at least 2 hours | at least 2 hours |
| Clearance above | 12" Open (304.8 mm) | 12" (30.5 cm) | 2 to 3 mm (about 1/10") | 250 mm (9.8 in) |
| Clearance at the sides | 0" (0 cm) | 2" (5.1 cm) | 5 inches (127mm) (12.7 cm) | 20 mm (0.8 in) |
| Clearance behind | 1" (25.4 mm) | 2" (5.1 cm) | 5 inches (127mm) (12.7 cm) | max. 75 mm (3 in) |
Similar True commercial refrigeration
| True STR1RRI89-1S | Installation Manual | 36 pages |
|---|---|---|
| True STM1R-1S | Installation Manual | 26 pages |
| True Commercial Refrigeration Installation Manual | Installation Manual | 300 pages |
| True Commercial Refrigeration Installation Manual | Installation Manual | 240 pages |
| True TSCI-150PR-SWG-R | Installation Manual | 68 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True GDM-49-SCI-HC | Installation Manual | 56 pages |
| True TBR32-RISZ1-L-B-S-1 | Installation Manual | 56 pages |