As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance above0" (0 mm)TVM (Non-FD)1" (25.4 mm)TVM-FD (Full Door)Typical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 10
Clearance at the sides0" (0 mm)TVM-FD (Full Door)Typical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 10
Clearance behind1" (25.4 mm)TVM-FD (Full Door)Typical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 10

True TVM-30-FD-HC questions

Answers taken from this manual. Each one links to the page it comes from.

How do I set a mechanical or knob temperature control?

#9 is coldest, #1 is warmest, and #0 or Off turns the compressor off.

Manual: page 30

What does dEF mean on the temperature display?

dEF means defrost is running; the display may briefly delay showing the temperature afterward.

Manual: page 31

Why must I leave ventilation clearances?

Keep all ventilation openings clear; insufficient ventilation voids the warranty.

Manual: page 10

How do I clean the door gasket?

Wash the gasket with warm soapy water; avoid sharp tools, knives, and full-strength cleaning products.

Manual: page 40

What happens during defrost in a refrigerator or freezer?

The compressor turns off during defrost, and the clearing method depends on the compartment.

  • Refrigerator: evaporator fans clear the evaporator coil.
  • Freezer: an electric heater clears the evaporator coil while the evaporator fan is off.

Manual: page 31

How do I restart the unit after cleaning the condenser?

Restore power after the condensing unit and rear grill are back in place.

  1. Disconnect power before servicing.
  2. Return the condensing unit to position and reinstall its base bolts.
  3. Reinstall the rear grill and restore power.
  4. Verify that the unit operates.

Manual: page 38

How do I install castors and level the appliance?
  1. Access the bottom and remove any installed leveling screws.
  2. Install braked castors at the front, then thread the castors into the frame rail or bottom.
  3. Check the level; at the low end, loosen the castor bolt and insert shims between the bearing and bottom rail.
  4. Use no more than four shims per castor, with multiple shim slots offset.
  5. Make each shim touch the castor stem, tighten the castors, and verify the appliance is level.
  6. Repeat the adjustment until the appliance is level and supported.

Manual: page 17

True TVM-30-FD-HC compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

True TVM-30-FD-HCOther Commercial RefrigeratorSummit FF64BCSSEdgeStar VBM101SS
Clearance above0" (0 mm)12" (30.5 cm)4“(102mm)1/2”
Clearance at the sides0" (0 mm)2" (5.1 cm)5” (127mm)1/2”
Clearance behind1" (25.4 mm)2" (5.1 cm)5” (127mm)3/4”

Similar True commercial refrigeration

True TVM-36SL-HCModel family TVM36SLHCInstallation Manual40 pages
True TSCI-150PR-SWG-RInstallation Manual68 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True GDM-49-SCI-HCInstallation Manual56 pages
True TBR32-RISZ1-L-B-S-1Installation Manual56 pages
True TBR32-RISZ1-L-B-S-1Service Manual56 pages
True GDM-23-HST02-HCInstallation Manual48 pages
True GDM-23-HST02-HCInstallation Manual48 pages
All True commercial refrigeration →