Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory settingNormalTCB-5R controllerTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 9
Fridge adjustment range38 ᵻ to 55ᵻTCB-5R temperature controllerTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 9
Clearance above86 inch (218.4 cm) needs more space than mostinstallation clearance above the Bakery CaseTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 5
Clearance at the sides12 inch (30.5 cm) needs more space than mostinstallation clearance at each sideTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 5
Clearance behind20 inch (50.8 cm) needs more space than mostinstallation clearance at the rearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 5

Turbo Air Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature range can the TCB-5R controller set?

38 ᵻ to 55ᵻ is the controller’s temperature range.

Manual: page 9

How do I adjust the temperature?

Press the down button to lower temperature or the up button to increase it.

Manual: page 9

How much clearance does the bakery case need during installation?

Use these installation clearances for the Bakery Case.

LocationMinimum clearance
Top86 inch
Rear20 inch
Each side12 inch

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all

Manual: page 5

Can I load product right after switching on?

No, wait until the unit reaches the desired temperature, and load only cold product.

Manual: page 9

Why is my Bakery Case warm?
  • A dirty condenser may reduce cooling. Check whether the condenser is clean.
  • Doors or curved glass may not be closed tightly. Close them securely.
  • Shelves may be installed incorrectly. Check their installation.
  • Products or pans may block airflow. Remove anything obstructing airflow.
  • Doors left open can cause frost. Turn off the thermostat about one hour to melt it.

Manual: page 14

Why is the curved glass sweating?
  • Something may be sitting on the curved glass. Remove it.
  • Overhead vents, air ducts, or fans may affect the glass. Check for these nearby.
  • Room conditions may differ from the design point. Check for 75 degrees Fahrenheit and 55% relative humidity.
  • The case temperature may be outside its specified range. Check that it is between 38 and 42 degrees.
  • Uneven or missing airflow may indicate failed anti moisture fans. Call Customer Service.

Manual: page 14

Turbo Air Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Turbo Air Commercial RefrigeratorOther Commercial RefrigeratorSummit AL57GEdgeStar VBM101SS
Fridge adjustment range38 ᵻ to 55ᵻ34 °F to 38 °F (1 °C, 3 °C)36 °F to 43 °F (2 °C, 6 °C)34 °F to 64 °F (1 °C, 18 °C)
Clearance above86 inch (218.4 cm)12" (30.5 cm)2 to 3 mm (about 1/10")1/2”
Clearance at the sides12 inch (30.5 cm)2" (5.1 cm)5 inches (127mm) (12.7 cm)1/2”
Clearance behind20 inch (50.8 cm)2" (5.1 cm)5 inches (127mm) (12.7 cm)3/4”

Similar Turbo Air commercial refrigeration

Turbo Air TGF-49FService Manual128 pages
Turbo Air PRO-26-2FService Manual54 pages
Turbo Air TSF-23SDService Manual53 pages
Turbo Air M3F24-1Service Manual46 pages
Turbo Air TSF-23SDService Manual46 pages
Turbo Air KGR12-2Service Manual41 pages
Turbo Air TST-28SDService Manual34 pages
Turbo Air TGM-11RV-N6Service Manual33 pages
All Turbo Air commercial refrigeration →