Related manuals

These manuals share their text with this one.

Avantco 178Z1F2A178Z1F2A, 178Z1F2AWMS, 178Z1FHC, 178Z1FWMS, 178Z1R2A, 178Z1R2AWMS …Shares large sectionsOwner's Manual · 10 pages
Avantco 178GDW23BB178GDW23BB, 178GDW49BBShares large sectionsUser Manual · 9 pages

Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range33 °F to 40 °F (1 °C, 4 °C)refrigerators, minimum and maximum cycling temperaturesTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 6
Freezer adjustment range-5 °F to 2 °F (-21 °C, -17 °C)freezers, minimum and maximum cycling temperaturesTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C)p. 6
Wait before useminimum of 24 hoursAfter the unit has been transported on its sidep. 4
Clearance at the sides3”recommended clearance for best performanceTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 5
Clearance behind3”recommended clearance for best performanceTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 5
DefrostAutomatic Defrost Cycleunits with automatic defrostp. 6
Room temperature range75 °F (24 °C)ambient temperature should not exceed this for best performanceTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 5

Avantco 178A23FHC questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature ranges are refrigerators and freezers set to?

Factory cycling ranges differ between refrigerators and freezers.

UnitCycle range
Refrigerator33 °F to 40 °F
Freezer-5 °F to 2 °F

Other brands: Other 32 °F (0 °C) to 41 °F (5 °C) · Liebherr b1 to b9 · Summit 36 °F/2 °C to 43 °F/6 °C Compare all

Manual: page 6

How do I adjust the minimum temperature on Controller #1?
  1. Hold SET for 1 second until the current minimum temperature flashes.
  2. Use the arrow buttons to choose the desired minimum temperature.
  3. Press SET again to save the setting.
  4. Allow for cabinet temperature fluctuations up to +7 °F above the minimum setting.
  5. Do not set the temperature too high, because unsafe maximum temperatures may result.

Manual: page 6

Why is condensation collecting on the cabinet or floor?
  • Relative humidity above 60%. Move the unit to an area below that humidity level.
  • Door slightly ajar. Close the door completely.
  • Gasket not sealing properly. Clean, repair, or replace the gasket as needed.

Manual: page 10

What should I do if the evaporator coil is iced over?

Unplug the unit and let the coil defrost.

  1. Unplug the unit and allow the evaporator coil to defrost.
  2. Check that the thermostat is not set too cold.
  3. Check that the door gaskets are sealing properly.

Manual: page 10

How do I clean the shelves and pilasters?
  1. Remove the shelves and shelf brackets.
  2. Lift each pilaster upward, then pull it outward.
  3. Wash the shelves and pilasters with mild soap and warm water.

Manual: page 9

How do I clean the condenser coil?
  1. Disconnect electrical power from the unit.
  2. Remove the front and base covers with a screwdriver.
  3. Brush or vacuum dirt and lint from the finned coil vertically.
  4. Clean the condenser with commercial condenser coil cleaner.
  5. Straighten bent condenser fins with a fin comb.
  6. Reinstall the front and base covers.
  7. Reconnect electrical power to the unit.

Manual: page 9

Can I load products as soon as the unit is plugged in?

No. Wait until the unit reaches the desired temperature before loading products; it keeps cold products cold, not warm products.

Manual: page 4

Can a glass-door model be changed to left-hinged?

No. A glass-door model cannot be changed to hinge on the left in the field.

Manual: page 5

How long should I wait before plugging in a refrigerator transported on its side?

At least 24 hours; let the unit stand upright before plugging it in.

Manual: page 4

How should I install shelves for proper airflow?

Install a raised-lip shelf with its lip upward and toward the cabinet’s rear to promote airflow.

Manual: page 4

Avantco 178A23FHC compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Avantco 178A23FHCOther Commercial RefrigeratorGram Commercial RefrigeratorSummit FF64BCSS
Fridge adjustment range33 °F to 40 °F (1 °C, 4 °C)34 °F to 38 °F (1 °C, 3 °C)2 to 12 °C (36 to 54 °F)36 °F/2 °C to 43 °F/6 °C
Freezer adjustment range-5 °F to 2 °F (-21 °C, -17 °C)-7°Fto -1 °F (-22 °C, -18 °C)-10 to -22 °C (14 to -8 °F)-11 °F/-24 °C to 11 °F/-12 °C
Wait before useminimum of 24 hoursat least 24 hoursat least 2 hours·
Clearance at the sides3”2" (5.1 cm)20 mm (0.8 in)5” (127mm)
Clearance behind3”2" (5.1 cm)max. 75 mm (3 in)5” (127mm)
Room temperature range75 °F (24 °C)below 90 °F (32 °C)+16C and +40 °C (104 °F)above 44 °F (7 °C) and below 90 °F (32 °C)

Similar Avantco commercial refrigeration

Avantco 178SS1F2HCModel family 178SS1F2HUser Manual9 pages
Avantco 178SS1F2HCModel family 178SS1F2HUser Manual8 pages
Avantco 178SSPPT1Model family 178SSUser Manual13 pages
Avantco 178SSUC27FHCModel family 178SSUser Manual10 pages
Avantco 178SSUC27FHCModel family 178SSUser Manual9 pages
Avantco 178SSCFT36HCModel family 178SSUser Manual9 pages
Avantco 178APPT49HCModel family 178AUser Manual12 pages
Avantco 178AU27FHCModel family 178AUser Manual8 pages
All Avantco commercial refrigeration →