As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range33 degrees Fahrenheit to 40 degrees Fahrenheitrefrigerator cycle temperaturesTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 5
Freezer adjustment range-5 degrees Fahrenheit to 2 degrees Fahrenheitfreezer cycle temperaturesTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C)p. 5
Clearance behind4”back of the unitTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 4
Defrostautomaticrefrigerator and freezer defrost cyclesp. 6

Avantco 178SSUC27FHC questions

Answers taken from this manual. Each one links to the page it comes from.

How do I change the minimum temperature setting?
  1. Hold SET for 1 sec until the current minimum temperature flashes.
  2. Use the arrow buttons to choose the minimum temperature.
  3. Press SET again to save the setting.

Manual: page 5

What temperature range does this refrigerator or freezer cycle through?

Refrigerators cycle from 33 degrees Fahrenheit to 40 degrees Fahrenheit; freezers cycle from -5 degrees Fahrenheit to 2 degrees Fahrenheit.

UnitMinimumMaximum
Refrigerator33 degrees Fahrenheit40 degrees Fahrenheit
Freezer-5 degrees Fahrenheit2 degrees Fahrenheit

Manual: page 5

What should I do when the evaporator coil is iced over?

Unplug the unit and let the evaporator coil defrost.

  1. Check that the thermostat is not set too cold.
  2. Check that the door gaskets seal properly.

Manual: page 9

How do I clean and replace a door gasket?

Clean door gaskets regularly, preferably weekly.

  1. Remove the gasket from the door frame.
  2. Soak it in warm water and soap for thirty (30) minutes.
  3. Dry it with a soft cloth and replace it.
  4. Check that the gasket seals properly.

Manual: page 8

What installation clearances does the unit need?

Maintain 4” behind the unit and 3” around all louvered or vented panels.

LocationClearance
Behind the unit4”
Louvered or vented panels3”

Manual: page 4

How much space should I leave between stored product and the back wall?

Leave two to four (2 to 4) inches between stored product and the back wall.

Manual: page 6

How do I start a manual defrost cycle on the freezer?

Automatic defrost runs at preset intervals, and a freezer cycle can also be started manually.

  1. Press the def button for approximately 5 seconds.
  2. Press the def button again to stop the cycle.

Manual: page 6

How do refrigerator and freezer defrost systems work?

Refrigerators and freezers remove frost using different automatic methods.

ApplianceDefrost method
RefrigeratorAir circulation melts frost; runoff evaporates.
FreezerElectric defrosting starts at preset intervals.

Manual: page 6

How long is the Avantco warranty for these units?

In the United States, coverage is 1 year for parts and labor; SSUC compressors receive 5 years under the additional warranty.

Manual: page 10

How do I contact Avantco about warranty service?
  1. Confirm the equipment was purchased from an authorized dealer.
  2. Locate the model number on the unit or inside the door jamb.
  3. Locate the bold number on the service plate.
  4. Call 1-800-678-5517 with both numbers.
  5. Contact Avantco before obtaining equipment service, or warranty coverage may be voided.

Manual: page 10

Avantco 178SSUC27FHC compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Avantco 178SSUC27FHCOther Commercial RefrigeratorSummit FF64BCSSTurbo Air PRO-26-2R
Fridge adjustment range33 degrees Fahrenheit to 40 degrees Fahrenheit34 °F to 38 °F (1 °C, 3 °C)36 °F/2 °C to 43 °F/6 °C‘1’ to ‘9’
Freezer adjustment range-5 degrees Fahrenheit to 2 degrees Fahrenheit-7°Fto -1 °F (-22 °C, -18 °C)-11 °F/-24 °C to 11 °F/-12 °Cʻ1ʼ to ʻ9ʼ
Clearance behind4”2" (5.1 cm)5” (127mm)5 inches (12.7 cm)

Similar Avantco commercial refrigeration

Avantco 178SSPPT1Model family 178SSUser Manual13 pages
Avantco 178A23FHCModel family 178A2Owner's Manual10 pages
Avantco 178SS1F2HCModel family 178SSUser Manual9 pages
Avantco 178SSCFT36HCModel family 178SSUser Manual9 pages
Avantco 178SS1F2HCModel family 178SSUser Manual8 pages
Avantco 178APPT49HCModel family 178User Manual12 pages
Avantco 178Z1F2AModel family 178Owner's Manual10 pages
Avantco 178GDW23BBModel family 178User Manual9 pages
All Avantco commercial refrigeration →