Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range33 degrees Fahrenheit to 40 degrees FahrenheitRefrigeratorsTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 4
Wait before use24 hoursAfter the unit has been transported on its sidep. 3
Clearance at the sides3”Around all louvered or vented panelsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 3
Clearance behind4”For best performanceTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 3
DefrostautomaticRefrigerators and freezersp. 5

Avantco 178APPT49HC questions

Answers taken from this manual. Each one links to the page it comes from.

How do I change the refrigerator’s minimum temperature?

Use the digital control to change the minimum temperature setting.

  1. Hold SET for 1 sec., until the current minimum temperature flashes.
  2. Use the arrow buttons to select the desired minimum temperature.
  3. Press SET again to save the setting.

Manual: page 4

What temperature range is specified for the refrigerator?

33 degrees Fahrenheit to 40 degrees Fahrenheit, with the refrigerator cycling within that range.

Manual: page 4

Why does the unit run for long periods when the evaporator coil is iced over?
  • Evaporator coil iced over. Unplug the unit, allow the coil to defrost, and check the thermostat is not set too cold.
  • Door gasket not sealing properly. Check that the door gasket seals properly.

Manual: page 12

Where should I install the refrigerator or freezer?

Use a strong, level surface indoors with good ventilation, away from equipment that produces heat or moisture.

Manual: page 3

How do I start or stop a manual defrost cycle?
  1. Hold the defrost button for approximately 3 seconds to start the manual cycle.
  2. Press the defrost button again to stop the cycle.

Manual: page 5

What does the Defrost LED mean?

The defrost cycle is running. Automatic defrost starts at preset intervals; refrigerator frost melts during compressor downtime and drains into the evaporator pan.

Manual: page 4, page 5

Avantco 178APPT49HC compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Avantco 178APPT49HCOther Commercial RefrigeratorSummit FF64BCSSWhynter CBM-815WS
Fridge adjustment range33 degrees Fahrenheit to 40 degrees Fahrenheit34 °F to 38 °F (1 °C, 3 °C)36 °F to 43 °F (2 °C, 6 °C)34 °F - 43 °F / 1 °C - 6 °C
Wait before use24 hoursat least 24 hoursabout 2 hoursabout 4 hours
Clearance at the sides3”2" (5.1 cm)5” (127mm)at least 5 inches (127mm) (12.7 cm)
Clearance behind4”2" (5.1 cm)5” (127mm)at least 5 inches (127mm) (12.7 cm)

Similar Avantco commercial refrigeration

Avantco 178A23FHCModel family 178AOwner's Manual10 pages
Avantco 178AU27FHCModel family 178AUser Manual8 pages
Avantco 178AU27FHCModel family 178AUser Manual8 pages
Avantco 178SSPPT1Model family 178User Manual13 pages
Avantco 178SSUC27FHCModel family 178User Manual10 pages
Avantco 178Z1F2AModel family 178Owner's Manual10 pages
Avantco 178SS1F2HCModel family 178User Manual9 pages
Avantco 178SSUC27FHCModel family 178User Manual9 pages
All Avantco commercial refrigeration →