Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge adjustment range | minimum temperature of 33 °F and maximum temperature of 40 °F (1 °C, 4 °C)Typical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 5 |
|---|---|---|
| Freezer adjustment range | minimum temperature of -5 °F and maximum temperature of 2 °F (-21 °C, -17 °C)Typical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 5 |
| Door-open alarm after | 15 minutes later than mostDoor left ajarTypical for commercial refrigeration: 1 to 5 minutes | p. 6 |
| Defrost | automaticUnit automatic defrost cycles | p. 7 |
Avantco 178Z1F2A questions
Answers taken from this manual. Each one links to the page it comes from.
How much clearance should I leave between stored products and the fan?
Leave at least 4" between stored products and the fan.
Manual: page 7
What does the door alarm mean?
After 15 minutes with the door ajar, an audible alarm sounds and the display shows dor.
Other brands: Other 2 minutes · Summit 60 seconds · True five (5) Compare all
Manual: page 6
Why isn't the compressor running?
- A blown fuse or tripped circuit breaker. Replace the fuse or reset the circuit breaker.
- An unplugged power cord. Plug in the power cord.
- A thermostat set too high. Set the thermostat to a lower temperature.
- The cabinet is defrosting. Wait until the defrost cycle ends.
Manual: page 10
Why isn't the interior light working?
- A poor switch connection. Turn the light switch off, then turn it back on.
- The bulb is disconnected. Insert the bulb correctly into its socket.
- A burned-out bulb. Replace the bulb.
Manual: page 10
Does this unit defrost automatically?
Yes. Automatic timers start defrost cycles at preset intervals; refrigerator coils defrost during compressor downtime, while freezer coils defrost electrically.
Manual: page 7
How do I start a manual defrost cycle?
- Hold the menu key for 3 seconds to open menu selection; “--” appears.
- Press the upper-left button to begin manual defrosting.
- Wait about 7 seconds for the display to return to normal.
Manual: page 7
How do I clean the fan blades and motor?
- Disconnect the power cord before cleaning any unit parts.
- Wipe the fan blades and motor with a soft cloth.
- If washing the blades, cover the motor to prevent moisture damage.
Manual: page 8
How do I clean the condenser coil?
- Locate the condenser coil behind the top panel.
- Brush or vacuum dirt and lint from the fins vertically.
- Apply a commercial condenser coil cleaner, such as Noble Chemical Tech Line.
Manual: page 9
How do I clean and replace a door gasket?
- Remove the gasket from the door frame.
- Soak it in warm, soapy water for thirty (30) minutes.
- Dry the gasket with a soft cloth and reinstall it.
- Check that the gasket seals properly after replacement.
Manual: page 9
Similar Avantco commercial refrigeration
| Avantco 178Z1R2AModel family 178Z1R2A | User Manual | 9 pages |
|---|---|---|
| Avantco 178SSPPT1Model family 178 | User Manual | 13 pages |
| Avantco 178APPT49HCModel family 178 | User Manual | 12 pages |
| Avantco 178SSUC27FHCModel family 178 | User Manual | 10 pages |
| Avantco 178SS1F2HCModel family 178 | User Manual | 9 pages |
| Avantco 178SSUC27FHCModel family 178 | User Manual | 9 pages |
| Avantco 178GDW23BBModel family 178 | User Manual | 9 pages |
| Avantco 178TUC27FHCModel family 178 | User Manual | 9 pages |