Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory settingoptimum temperaturesnew refrigeratorTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 4
Fridge adjustment range33 degrees Fahrenheit to 40 degrees FahrenheitTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 4
Freezer factory settingoptimum temperaturesnew freezerTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C)p. 4
Wait before use24 hoursif transported on its sidep. 3
Clearance at the sides3" (7.6 cm)around all louvered or vented panelsTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 3
Clearance behind4" (10.2 cm)for best performance, behind the unitTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 3
Defrostautomaticrefrigerator and freezerp. 5

Avantco 178SSPPT1 questions

Answers taken from this manual. Each one links to the page it comes from.

What temperature range does the refrigerator cycle through?

33 degrees Fahrenheit to 40 degrees Fahrenheit is the refrigerator’s cycling range.

Manual: page 4

How do I clear an iced evaporator coil?

Unplug the unit, then correct the conditions that can cause the coil to ice over.

  1. Disconnect the unit from power.
  2. Wait until the evaporator coil has completely defrosted.
  3. Check that the thermostat is not set too cold.
  4. Check that the door gasket seals properly.

Manual: page 13

Why does the unit run for long periods?
  • Warm product was added. Allow enough time for the product to cool.
  • The door stays open or ajar. Close it when unused and avoid prolonged opening.
  • The door gasket is not sealing. Seat it fully, wash it, check its condition, and replace it if needed.
  • The condenser coil is dirty. Clean the condenser coil.
  • The evaporator coil is iced over. Unplug the unit and let the coil defrost.

Manual: page 13

How do I start or stop a manual defrost cycle?

Use the defrost button to start the cycle, then repeat the action to stop it.

  1. Press the defrost button for approximately 3 seconds.
  2. Repeat the press to stop the defrost cycle.

Manual: page 5

What does the Defrost LED mean?

The Defrost LED means the defrost cycle is running.

Manual: page 4

Avantco 178SSPPT1 compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Avantco 178SSPPT1Other Commercial RefrigeratorSummit FF64BCSSWhynter CBM-815WS
Fridge adjustment range33 degrees Fahrenheit to 40 degrees Fahrenheit34 °F to 38 °F (1 °C, 3 °C)36 °F to 43 °F (2 °C, 6 °C)34 °F - 43 °F / 1 °C - 6 °C
Wait before use24 hoursat least 24 hoursabout 2 hoursabout 4 hours
Clearance at the sides3" (7.6 cm)2" (5.1 cm)5” (127mm)at least 5 inches (127mm) (12.7 cm)
Clearance behind4" (10.2 cm)2" (5.1 cm)5” (127mm)at least 5 inches (127mm) (12.7 cm)

Similar Avantco commercial refrigeration

Avantco 178A23FHCModel family 178A2Owner's Manual10 pages
Avantco 178SSUC27FHCModel family 178SSUser Manual10 pages
Avantco 178SS1F2HCModel family 178SSUser Manual9 pages
Avantco 178SSUC27FHCModel family 178SSUser Manual9 pages
Avantco 178SSCFT36HCModel family 178SSUser Manual9 pages
Avantco 178SS1F2HCModel family 178SSUser Manual8 pages
Avantco 178APPT49HCModel family 178User Manual12 pages
Avantco 178Z1F2AModel family 178Owner's Manual10 pages
All Avantco commercial refrigeration →