Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge adjustment range33 degrees Fahrenheit to 40 degrees FahrenheitTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C)p. 6
Freezer adjustment range-5 degrees Fahrenheit to 2 degrees FahrenheitTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C)p. 6
Wait before useminimum of 24 hoursif transported on its sidep. 3
Door-open alarm after15 minutes later than mostDoor left ajarTypical for commercial refrigeration: 1 to 5 minutesp. 6
Clearance at the sides6” needs more space than mostfor best performanceTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 3
Clearance behind6” needs more space than mostfor best performanceTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 3
DefrostautomaticUnit defrost systemAutomatic defrostRefrigerator and freezerp. 7

Avantco 178Z1R2A questions

Answers taken from this manual. Each one links to the page it comes from.

Why does the cabinet temperature rise above my set minimum?

The temperature can rise up to +7 degrees over the set minimum because the compressor runs and shuts off.

Manual: page 6

Why is condensation collecting on the cabinet or floor?

A door gasket that fails to seal can cause condensation on the cabinet or floor. Clean, repair, or replace the gasket as needed.

Manual: page 9

How do I clean the door gasket?
  1. Remove the door gasket from the door frame.
  2. Soak it in warm water and soap for thirty (30) minutes.
  3. Dry it with a soft cloth, then replace it.
  4. Check that the gasket seals properly after replacement.

Manual: page 8

How does this unit defrost?

The refrigerator melts frost during compressor downtime, while the freezer uses electric defrosting. Timers start automatic cycles at preset intervals.

Manual: page 7

How long should I wait before plugging in a unit transported on its side?

Wait a minimum of 24 hours before plugging in the unit.

Manual: page 3

Avantco 178Z1R2A compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Avantco 178Z1R2AGram Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSS
Fridge adjustment range33 degrees Fahrenheit to 40 degrees Fahrenheit2 to 12 °C (36 to 54 °F)34 °F to 38 °F (1 °C, 3 °C)36 °F to 43 °F (2 °C, 6 °C)
Freezer adjustment range-5 degrees Fahrenheit to 2 degrees Fahrenheit-10 to -22 °C (14 to -8 °F)-7°Fto -1 °F (-22 °C, -18 °C)·
Wait before useminimum of 24 hoursat least 2 hoursat least 24 hoursabout 2 hours
Door-open alarm after15 minutesmore than 2 minutes·60 seconds
Clearance at the sides6”20 mm (0.8 in)2" (5.1 cm)5” (127mm)
Clearance behind6”max. 75 mm (3 in)2" (5.1 cm)5” (127mm)

Similar Avantco commercial refrigeration

Avantco 178Z1F2AModel family 178Z1F2AOwner's Manual10 pages
Avantco 178SSPPT1Model family 178User Manual13 pages
Avantco 178APPT49HCModel family 178User Manual12 pages
Avantco 178A23FHCModel family 178Owner's Manual10 pages
Avantco 178SSUC27FHCModel family 178User Manual10 pages
Avantco 178SS1F2HCModel family 178User Manual9 pages
Avantco 178SSUC27FHCModel family 178User Manual9 pages
Avantco 178GDW23BBModel family 178User Manual9 pages
All Avantco commercial refrigeration →