Have a question about the Gram Commercial Refrigerator? The AI assistant looks through this manual and shows the pages with the answer.
Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge adjustment range | -5/+12Refrigerator cabinet type+2/+12Refrigerator extended cabinet typeTypical for commercial refrigeration: 34 to 45 °F (1 to 7 °C) | p. 17 |
|---|---|---|
| Freezer adjustment range | -22 /-10Freezer cabinet typeTypical for commercial refrigeration: -8 to 3 °F (-22 to -16 °C) | p. 17 |
Gram Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
What temperature ranges are listed for each cabinet type?
Freezer uses -22 /-10, refrigerator -5/+12, and refrigerator extended +2/+12.
| Cabinet type | Temperature area (°C/°F) |
|---|---|
| Freezer | -22 /-10 |
| Refrigerator | -5/+12 |
| Refrigerator extended | +2/+12 |
Manual: page 17
What does SP mean on the temperature controller?
SP is the controller's temperature setpoint parameter.
Manual: page 17
How do I start a manual defrost?
Press the defrosting button to initiate manual defrosting.
Manual: page 10
What does the defrost status indicator mean?
The indicator shows the cabinet’s defrost status.
| Indicator state | Meaning |
|---|---|
| Lit | Defrosting is in progress. |
| Flashing | Drip time is underway after defrosting. |
| Flashing | Defrosting could not start because the compressor is operating. |
Manual: page 9
What fitting do I need to change the door hinge side?
A special lower fitting/hinge is needed: Door fitting right, 763251794, or Door fitting left, 763251798.
Manual: page 27
How soon can I restart the appliance after turning it off?
Wait a minimum of 3 minutes before switching it on again.
Manual: page 6
Why is the cabinet showing a door alarm?
The door is open or not properly closed. Close it properly; the alarm cancels, but remains in the HACCP log.
Manual: page 12
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| COH | Condenser temperature is too high. | p. 18 | |
| CSd | Compressor blocked because condenser temperature is too high. | p. 18 | |
| Pr1 | Room sensor error. | p. 18 | |
| ∟d | Door alarm. | p. 24 |
Gram Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Gram Commercial Refrigerator | Other Commercial Refrigerator | Summit FF64BCSS | U-Line UCRE552-SS61A | |
|---|---|---|---|---|
| Fridge adjustment range | -5/+12 | 34 °F to 38 °F (1 °C, 3 °C) | 36 °F/2 °C to 43 °F/6 °C | -2 °C (-28 °F) to 8 °C (46 °F) |
| Freezer adjustment range | -22 /-10 | -7°Fto -1 °F (-22 °C, -18 °C) | -11 °F/-24 °C to 11 °F/-12 °C | -25 °C (-13 °F) to -10 °C (14 °F) |
Similar Gram commercial refrigeration
| Gram Commercial Refrigeration Instruction Manual | Instruction Manual | 154 pages |
|---|---|---|
| Gram Commercial Refrigeration User Manual | User Manual | 140 pages |
| Gram IO-REF-1455 | Instruction Manual | 132 pages |
| Gram Commercial Refrigeration Instruction Manual | Instruction Manual | 131 pages |
| Gram COMPACT 600 Gram Refrigerator | User Manual | 124 pages |
| Gram IO-REF-1453 | Instruction Manual | 124 pages |
| Gram IO-REF-1421 | Instruction Manual | 120 pages |
| Gram IO-REF-1419 | Operating Instructions | 120 pages |