Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | 38º FFactory setting for the refrigerator cabinetTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 10 |
|---|---|---|
| Clearance above | 12 in. (30.5 cm)RIS and RISA refrigeratorsTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 7 |
| Clearance at the sides | 0.0 in. (0 cm)RIS and RISA refrigerators, left and right sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 7 |
| Clearance behind | 0.0 in. (0 cm) needs less space than mostRIS and RISA refrigerators, rearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 7 |
| Defrost | automaticThe refrigerator defrosts as needed | p. 11 |
Victory RIS-2D-S1-HC questions
Answers taken from this manual. Each one links to the page it comes from.
Why does the refrigerator cool but run almost continuously?
- Dirty condenser. Clean the condenser.
- Iced evaporator. Defrost the evaporator.
- Room temperature is too high. Lower the room temperature.
- Temperature control problem. Have the control adjusted or replaced.
Manual: page 27
What are the cabinet dimensions for the RIS-2D-S1-HC?
68 7/8 X 36 5/8 X 84 1/2 inches, solid-door cabinet.
Manual: page 6
How much installation clearance does this refrigerator need?
Use these clearances when positioning the refrigerator.
| Location | Clearance |
|---|---|
| Top | 12 in. |
| Rear | 0.0 in. |
| Left side | 0.0 in. |
| Right side | 0.0 in. |
Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all
Manual: page 7
How do I clean the door gasket?
Use a soft scrub brush and warm (100oF to 110oF) detergent solution on the gasket; rinse with clean water and air dry.
Manual: page 24
How do I manually defrost the refrigerator?
Push and immediately release the “melting” or defrost button to begin manual defrosting.
Manual: page 11
Why does the refrigerator defrost without a schedule?
It defrosts automatically as needed, so no set defrost time applies.
Manual: page 11
What should I check if the refrigerator is silent and not cooling?
- Unit unplugged. Connect it to the proper voltage circuit.
- Fuse or circuit breaker tripped. Replace the fuse or reset the breaker.
- Loose power cord plug. Check the outlet connection and replace it as needed.
Manual: page 27
Why does the refrigerator seem to run all the time?
- Dirty condenser. Clean the condenser.
- Evaporator iced over. Defrost the evaporator.
- High-temperature environment. Reduce the room temperature.
- Temperature control problem. Adjust or replace the control.
Manual: page 27
How do I view active alarms on the control panel?
Press and release ALARM LOG to open active alarms and the alarm menu.
Manual: page 17
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| Afr | Frost protection | p. 22 | |
| AtS | Restart in pump down | p. 22 | |
| CE | Configuration write error | p. 22 | |
| cht | High condensing temperature warning | p. 22 | |
| COM | VCC communication error | p. 22 | |
| dA | Delayed alarm from external contact | p. 22 | |
| dor | Door open | p. 22 | |
| E1 | Probe 1 faulty or disconnected | p. 22 | |
| E2 | Probe 2 faulty or disconnected | p. 22 | |
| E3 | Probe 3 faulty or disconnected | p. 22 | |
| E4 | Probe 4 faulty or disconnected | p. 22 | |
| E5 | Probe 5 faulty or disconnected | p. 22 | |
| E6 | Probe S1H faulty or disconnected | p. 22 | |
| E7 | Probe S2H faulty or disconnected | p. 22 | |
| Ed1 | Defrost ended after maximum time | p. 22 | |
| Ed2 | Second evaporator defrost ended after maximum time | p. 22 | |
| EHI | High power supply voltage alarm | p. 22 | |
| ELO | Low power supply voltage alarm | p. 22 | |
| Etc | Clock error | p. 22 | |
| GHI | Generic alarm high threshold | p. 23 | |
| GLO | Generic alarm low threshold | p. 23 | |
| HA | High temperature during operation HACCP alarm | p. 23 | |
| HF | High temperature after blackout HACCP alarm | p. 23 | |
| HI | High temperature | p. 23 | |
| IA | Immediate alarm from external contact | p. 23 | |
| LO | Low temperature | p. 23 | |
| LP | Low pressure | p. 23 | |
| MAn | Output status overridden in manual mode | p. 23 | |
| Pd | Maximum pump down time | p. 23 | |
| rE | Control probe faulty or disconnected | p. 23 | |
| rSF | Refrigerant leak alarm | Switch off all actuators | p. 23 |
| SF | Configuration not completed correctly | p. 23 | |
| SrC | Maintenance request | p. 23 | |
| UCF | VCC operation error | p. 23 |
Victory RIS-2D-S1-HC compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Victory RIS-2D-S1-HC | Other Commercial Refrigerator | Summit FF64BCSS | Gram Commercial Refrigerator | |
|---|---|---|---|---|
| Fridge factory setting | 38º F | 34 °F to 38 °F (1 °C, 3 °C) | 38 °F, or 3 °C | 5 °C (41 °F) |
| Clearance above | 12 in | 12" (30.5 cm) | 4” (102mm) | 250 mm (9.8 in) |
| Clearance at the sides | 0.0 in | 2" (5.1 cm) | 5” (127mm) | 20 mm (0.8 in) |
| Clearance behind | 0.0 in | 2" (5.1 cm) | 5” (127mm) | max. 75 mm (3 in) |
Similar Victory commercial refrigeration
| Victory RS-2D-S1-EW-HC | Installation & Operation Manual | 34 pages |
|---|---|---|
| Victory RFS | Operating Instructions | 30 pages |
| Victory VERSA-1D-GD-HC | Installation & Operation Manual | 53 pages |
| Victory VEFSA-1D-HD-HC-* | Installation & Operation Manual | 48 pages |
| Victory VBCFT-20-202PU-HC | Operating Instructions | 42 pages |
| Victory Commercial Refrigeration Operating Instructions | Operating Instructions | 38 pages |
| Victory Commercial Refrigeration Operating Instructions | Operating Instructions | 31 pages |
| Victory VWR36HC********* | Installation & Operation Manual | 31 pages |