| Wait before use | 3 hoursif the unit is tipped onto its back | p. 9 |
|---|---|---|
| Clearance at the sides | 0.0 in. (0 cm)left and right sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 8 |
| Clearance behind | 0.0 in. (0 cm) needs less space than mostrearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 8 |
| Defrost | automatic | p. 12 |
Victory RS-2D-S1-EW-HC questions
Answers taken from this manual. Each one links to the page it comes from.
Why does my refrigerator run constantly?
- Dirty condenser. Clean the condenser.
- Iced evaporator. Defrost the evaporator.
- High room temperature. Reduce the room temperature.
Manual: page 28
What installation clearances does the refrigerator need?
Leave the following minimum clearances around the refrigerator.
| Location | Clearance |
|---|---|
| Top | 12 in. |
| Rear | 0.0 in. |
| Left side | 0.0 in. |
| Right side | 0.0 in. |
Other brands: Other 100 mm (4”) (3.9 in) · Summit 5” (127mm) · True 1" (25.4 mm) Compare all
Manual: page 8
How do I level the refrigerator after installation?
Level the cabinet after placing it in position.
- Measure the level on the headrail.
- For casters, place large washers between the ½' stud and cabinet-bottom holes.
- For legs, rotate each leg foot with an adjustable wrench.
- Do not loosen casters; keep them tightly secured to the cabinet.
Manual: page 9
How do I clean the door gasket?
- Remove food and shelves; keep food at a safe temperature.
- Disconnect power to the refrigerator.
- Scrub the door gasket with warm 100oF to 110oF detergent solution and a soft brush.
- Rinse with clean water and let the gasket air dry.
- Return shelves, restore power, and replace food after it reaches a safe temperature.
Manual: page 25
How does this refrigerator defrost?
Automatically as needed, with no scheduled defrost time. For manual defrost, push and immediately release the melting or defrost button.
Manual: page 12
What should I check if the refrigerator is silent and not cooling?
- Power is disconnected. Connect the refrigerator to the proper voltage circuit.
- The fuse or circuit breaker has tripped. Replace the fuse or reset the breaker.
- The power plug is loose. Check the outlet connection and replace it as needed.
Manual: page 28
How do I view active alarms on the refrigerator?
Press and release ALARM LOG to view active alarms and open the alarm menu.
Manual: page 18
Error codes in this manual
| Code | Meaning | What to do | |
|---|---|---|---|
| Afr | Frost protection activated. | p. 23 | |
| AtS | Restart is in pump down. | p. 23 | |
| CE | Configuration write error. | p. 23 | |
| cht | High condensing temperature warning. | p. 23 | |
| COM | VCC communication error. | p. 23 | |
| dA | Delayed alarm from an external contact. | p. 23 | |
| dor | Door is open. | p. 23 | |
| E1 | Probe 1 is faulty or disconnected. | p. 23 | |
| E2 | Probe 2 is faulty or disconnected. | p. 23 | |
| E3 | Probe 3 is faulty or disconnected. | p. 23 | |
| E4 | Probe 4 is faulty or disconnected. | p. 23 | |
| E5 | Probe 5 is faulty or disconnected. | p. 23 | |
| E6 | Probe S1H is faulty or disconnected. | p. 23 | |
| E7 | Probe S2H is faulty or disconnected. | p. 23 | |
| Ed1 | Defrost ended after the maximum time. | p. 23 | |
| Ed2 | Second evaporator defrost ended after maximum time. | p. 23 | |
| EHI | High power supply voltage alarm. | p. 23 | |
| ELO | Low power supply voltage alarm. | p. 23 | |
| Etc | Clock error. | p. 23 | |
| GHI | Generic alarm high threshold. | p. 24 | |
| GLO | Generic alarm low threshold. | p. 24 | |
| HA | HACCP high temperature alarm during operation. | p. 24 | |
| HF | HACCP high temperature alarm after a blackout. | p. 24 | |
| HI | High temperature. | p. 24 | |
| IA | Immediate alarm from an external contact. | p. 24 | |
| LO | Low temperature. | p. 24 | |
| LP | Low pressure. | p. 24 | |
| MAn | Output status overridden in manual mode. | p. 24 | |
| Pd | Maximum pump down time reached. | p. 24 | |
| rE | Control probe is faulty or disconnected. | p. 24 | |
| rSF | Refrigerant leak alarm. | Switch off all actuators. | p. 24 |
| SF | Configuration was not completed correctly. | p. 24 | |
| SrC | Maintenance is requested. | p. 24 | |
| UCF | VCC operation error. | p. 24 |
Victory RS-2D-S1-EW-HC compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Victory RS-2D-S1-EW-HC | Other Commercial Refrigerator | Summit FF64BCSS | True STA1DT-2HS-HC | |
|---|---|---|---|---|
| Wait before use | 3 hours | at least 24 hours | about 2 hours | 24 hours |
| Clearance at the sides | 0.0 in | 2" (5.1 cm) | 5” (127mm) | 0" (0 cm) |
| Clearance behind | 0.0 in | 2" (5.1 cm) | 5” (127mm) | 1" (25.4 mm) |
Similar Victory commercial refrigeration
| Victory RIS-2D-S1-HC | Installation & Operation Manual | 32 pages |
|---|---|---|
| Victory RFS | Operating Instructions | 30 pages |
| Victory VERSA-1D-GD-HC | Installation & Operation Manual | 53 pages |
| Victory VEFSA-1D-HD-HC-* | Installation & Operation Manual | 48 pages |
| Victory VBCFT-20-202PU-HC | Operating Instructions | 42 pages |
| Victory Commercial Refrigeration Operating Instructions | Operating Instructions | 38 pages |
| Victory Commercial Refrigeration Operating Instructions | Operating Instructions | 31 pages |
| Victory VWR36HC********* | Installation & Operation Manual | 31 pages |