Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before use3 hoursif the unit is tipped onto its backp. 9
Clearance at the sides0.0 in. (0 cm)left and right sidesTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 8
Clearance behind0.0 in. (0 cm) needs less space than mostrearTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 8
Defrostautomaticp. 12

Victory RS-2D-S1-EW-HC questions

Answers taken from this manual. Each one links to the page it comes from.

Why does my refrigerator run constantly?
  • Dirty condenser. Clean the condenser.
  • Iced evaporator. Defrost the evaporator.
  • High room temperature. Reduce the room temperature.

Manual: page 28

What installation clearances does the refrigerator need?

Leave the following minimum clearances around the refrigerator.

LocationClearance
Top12 in.
Rear0.0 in.
Left side0.0 in.
Right side0.0 in.

Other brands: Other 100 mm (4”) (3.9 in) · Summit 5” (127mm) · True 1" (25.4 mm) Compare all

Manual: page 8

How do I level the refrigerator after installation?

Level the cabinet after placing it in position.

  1. Measure the level on the headrail.
  2. For casters, place large washers between the ½' stud and cabinet-bottom holes.
  3. For legs, rotate each leg foot with an adjustable wrench.
  4. Do not loosen casters; keep them tightly secured to the cabinet.

Manual: page 9

How do I clean the door gasket?
  1. Remove food and shelves; keep food at a safe temperature.
  2. Disconnect power to the refrigerator.
  3. Scrub the door gasket with warm 100oF to 110oF detergent solution and a soft brush.
  4. Rinse with clean water and let the gasket air dry.
  5. Return shelves, restore power, and replace food after it reaches a safe temperature.

Manual: page 25

How does this refrigerator defrost?

Automatically as needed, with no scheduled defrost time. For manual defrost, push and immediately release the melting or defrost button.

Manual: page 12

What should I check if the refrigerator is silent and not cooling?
  • Power is disconnected. Connect the refrigerator to the proper voltage circuit.
  • The fuse or circuit breaker has tripped. Replace the fuse or reset the breaker.
  • The power plug is loose. Check the outlet connection and replace it as needed.

Manual: page 28

How do I view active alarms on the refrigerator?

Press and release ALARM LOG to view active alarms and open the alarm menu.

Manual: page 18

Error codes in this manual

CodeMeaningWhat to do
AfrFrost protection activated.p. 23
AtSRestart is in pump down.p. 23
CEConfiguration write error.p. 23
chtHigh condensing temperature warning.p. 23
COMVCC communication error.p. 23
dADelayed alarm from an external contact.p. 23
dorDoor is open.p. 23
E1Probe 1 is faulty or disconnected.p. 23
E2Probe 2 is faulty or disconnected.p. 23
E3Probe 3 is faulty or disconnected.p. 23
E4Probe 4 is faulty or disconnected.p. 23
E5Probe 5 is faulty or disconnected.p. 23
E6Probe S1H is faulty or disconnected.p. 23
E7Probe S2H is faulty or disconnected.p. 23
Ed1Defrost ended after the maximum time.p. 23
Ed2Second evaporator defrost ended after maximum time.p. 23
EHIHigh power supply voltage alarm.p. 23
ELOLow power supply voltage alarm.p. 23
EtcClock error.p. 23
GHIGeneric alarm high threshold.p. 24
GLOGeneric alarm low threshold.p. 24
HAHACCP high temperature alarm during operation.p. 24
HFHACCP high temperature alarm after a blackout.p. 24
HIHigh temperature.p. 24
IAImmediate alarm from an external contact.p. 24
LOLow temperature.p. 24
LPLow pressure.p. 24
MAnOutput status overridden in manual mode.p. 24
PdMaximum pump down time reached.p. 24
rEControl probe is faulty or disconnected.p. 24
rSFRefrigerant leak alarm.Switch off all actuators.p. 24
SFConfiguration was not completed correctly.p. 24
SrCMaintenance is requested.p. 24
UCFVCC operation error.p. 24
All Victory error codes →

Victory RS-2D-S1-EW-HC compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Victory RS-2D-S1-EW-HCOther Commercial RefrigeratorSummit FF64BCSSTrue STA1DT-2HS-HC
Wait before use3 hoursat least 24 hoursabout 2 hours24 hours
Clearance at the sides0.0 in2" (5.1 cm)5” (127mm)0" (0 cm)
Clearance behind0.0 in2" (5.1 cm)5” (127mm)1" (25.4 mm)

Similar Victory commercial refrigeration

Victory RIS-2D-S1-HCInstallation & Operation Manual32 pages
Victory RFSOperating Instructions30 pages
Victory VERSA-1D-GD-HCInstallation & Operation Manual53 pages
Victory VEFSA-1D-HD-HC-*Installation & Operation Manual48 pages
Victory VBCFT-20-202PU-HCOperating Instructions42 pages
Victory Commercial Refrigeration Operating InstructionsOperating Instructions38 pages
Victory Commercial Refrigeration Operating InstructionsOperating Instructions31 pages
Victory VWR36HC*********Installation & Operation Manual31 pages
All Victory commercial refrigeration →