| Wait before use | at least 3 hoursAfter the appliance has been laid on its back or tipped | p. 3 |
|---|---|---|
| Clearance above | 500mm needs more space than mostcabinets with top-mounted systemsTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm) | p. 2 |
| Clearance at the sides | 50mmall other cabinets, around the unitTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 2 |
| Clearance behind | 50mmall other cabinets, around the unitTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 2 |
| Defrost | automaticAppliances with automatic defrostmanualLA135 and LA400 | p. 5 |
Williams Commercial Refrigerator questions
Answers taken from this manual. Each one links to the page it comes from.
Why is the cabinet not maintaining temperature?
- Dirty condenser. Clean it.
- Restricted air circulation. Remove the restriction.
- Defective fan motor. Contact an engineer.
- Defective compressor relay. Contact an engineer.
- Loose electrical connection. Contact an engineer.
Manual: page 9
The cabinet is not operating. What should I check?
Check the fuse or power source first; the listed cause is no power supply.
Manual: page 9
What spacing do Thermowell wall brackets require?
Bracket spacing depends on the Thermowell model.
| Model | Spacing | Fixing points |
|---|---|---|
| TW9 | 918mm apart | 2 points |
| TW15 | 724mm apart | 3 points |
| TW18 | 900mm apart | 3 points |
Manual: page 2
How do I replace a damaged door gasket?
- Pull the existing gasket out.
- Push the new gasket into the channel at the center.
- Work along the channel, pressing the gasket into place.
Manual: page 8
What does dF mean on the display?
dF means the appliance is defrosting; the defrost indicator also lights during the cycle. Automatic defrost can briefly raise the cabinet temperature without affecting stored product.
Manual: page 5
How long should I wait before restarting after the appliance was tipped?
Wait at least 3 hours with the appliance upright before switching it on.
Other brands: Other 24 hours · Summit about 2 hours · True 24 hours Compare all
Manual: page 3
How do I reset the flashing condenser cleaning light?
- Press and hold the condenser cleaning button for 5 seconds.
- The flashing LED is canceled, and the temperature is displayed.
Manual: page 4
Williams Commercial Refrigerator compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Williams Commercial Refrigerator | Other Commercial Refrigerator | Summit FF64BCSS | True Commercial Refrigerator | |
|---|---|---|---|---|
| Wait before use | at least 3 hours | at least 24 hours | about 2 hours | 24 hours |
| Clearance above | 500mm | 12" (30.5 cm) | 4” (102mm) | 1" (25.4 mm) |
| Clearance at the sides | 50mm | 2" (5.1 cm) | 5” (127mm) | 0" (0 mm) |
| Clearance behind | 50mm | 2" (5.1 cm) | 5” (127mm) | 1" (25.4 mm) |
Similar Williams commercial refrigeration
| Williams Downloads | Williams Refrigeration | Commercial Refrigeration Manufact | Operating Instructions | 20 pages |
|---|---|---|
| Williams Commercial Refrigeration Operating Instructions | Operating Instructions | 16 pages |
| Williams MHC10 | Operating Instructions | 12 pages |
| Williams Commercial Refrigeration Operating Instructions | Operating Instructions | 12 pages |
| Williams Refrigeration Australia Operator and User Manual for Commercial Refrigeration Units | User Manual | 12 pages |
| Williams Refrigeration Australia Operator and User Manual | User Manual | 12 pages |