Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Fridge factory setting1 °C to 4 °C (34 °F, 39 °F) colder than mostH General Purpose0° to 3 °C (37 °F)CF Chilled FoodTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C)p. 4
Freezer factory setting, 18° to, 22 °C (72 °F) warmer than mostL Frozen FoodTypical for commercial refrigeration: -4 to 0 °F (-20 to -18 °C)p. 4
Wait before useat least two hoursAfter tilting during transport or positioningp. 4
Clearance above300 mm (11.8 in)Upright cabinetTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 4
Clearance at the sides100 mm (3.9 in)Under-counter cabinetTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 5
Clearance behind100 mm (3.9 in)Under-counter cabinetTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 5
DefrostautomaticForced draught cabinetsautomatic defrostAll forced draught cabinetsp. 6

Williams Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I remove ice from the evaporator?
  1. Move product to another storage area, such as a refrigerator.
  2. Turn the cabinet OFF with the doors and well open.
  3. Leave the cabinet overnight.
  4. Turn the unit back ON only after all ice completely defrosts.

Manual: page 10

Why is my cabinet temperature too high after defrost?

Wait for defrost to end; it may take up to 20 mins.

Manual: page 10

What clearance does an upright Williams cabinet need?

Upright cabinets need these minimum ventilation clearances.

LocationMinimum clearance
Top300 mm
Rear100 mm
Sides100 mm

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all

Manual: page 4

What clearance does an under-counter cabinet need?

Under-counter cabinets need rear and side clearance plus unobstructed airflow at the condensing unit.

LocationRequirement
Rear100 mm minimum
Sides100 mm minimum
Condensing unit frontKeep clear for airflow

Other brands: Other 100 mm (4”) (3.9 in) · Summit 5” (127mm) · True 1" (25.4 mm) Compare all

Manual: page 5

How do I clean the door gasket?

Clean the gasket weekly with warm mild soapy water and a soft cloth; avoid harsh detergents and sharp knives.

Manual: page 7

Do I need to manually defrost the refrigerator or freezer?

No. The refrigerator or freezer defrosts automatically, so manual defrosting is not needed.

Manual: page 8

Why do I hear steam or boiling-water sounds during defrosting?

Automatic defrost melts evaporator ice and moisture in a vaporising tray, which can produce steam or boiling-water sounds; this is normal.

Manual: page 6

Williams Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Williams Commercial RefrigeratorOther Commercial RefrigeratorSummit FF64BCSSGram Commercial Refrigerator
Fridge factory setting1 °C to 4 °C (34 °F, 39 °F)34 °F to 38 °F (1 °C, 3 °C)38 °F/3 °C5 °C (41 °F)
Freezer factory setting, 18° to, 22 °C (72 °F)-7°Fto -1 °F (-22 °C, -18 °C)0 °F/-18 °C-18 °C (0 °F)
Clearance above300 mm (11.8 in)12" (30.5 cm)4“(102mm)250 mm (9.8 in)
Clearance at the sides100 mm (3.9 in)2" (5.1 cm)5” (127mm)20 mm (0.8 in)
Clearance behind100 mm (3.9 in)2" (5.1 cm)5” (127mm)max. 75 mm (3 in)