Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Wait before useat least 1 hourCabinet has been laid on its back or tippedp. 3
Door-open alarm after5 minutesDoor left openTypical for commercial refrigeration: 1 to 5 minutesp. 4
Clearance above500mm needs more space than mostcabinets with top-mounted systems, between cabinet top and ceilingTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 2
Clearance at the sides50mmall other cabinets, minimum clearance around the unitTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 2
DefrostautomaticFresh Meat (M), Freezer (L), and Chilled Food (CF) cabinetsmanualLA135 and LA400 cabinetsp. 4

Williams Commercial Refrigerator questions

Answers taken from this manual. Each one links to the page it comes from.

How do I clear frost from a LA135 or LA400 cabinet?

Turn the unit off periodically, usually overnight, so frost on the evaporator can melt.

Manual: page 4

How do I clean or replace a damaged door gasket?

Clean the gasket with warm soapy water, or replace it if damaged.

  1. Wipe the gasket with warm soapy water and a soft cloth.
  2. Dry the gasket completely before closing the door.
  3. Do not scrape the gasket with a sharp knife.
  4. Pull the damaged gasket out of its channel.
  5. Push the replacement into the channel, starting at the center.
  6. Work around the remaining sides, pressing the corners in last.

Manual: page 7

How much clearance does the cabinet need around it?
  • Top-mounted systems: leave 500mm between the cabinet top and ceiling.
  • Other cabinets: provide at least 50mm around the unit.
  • Keep vents clear, and do not stack boxes on top or in front.

Other brands: Other 12" (30.5 cm) · Summit 4“(102mm) · True 1" (25.4 mm) Compare all

Manual: page 2

How does automatic defrost work on Williams cabinets?

Automatic defrost runs at preset intervals; dF appears, and the slight temperature rise does not affect stored product.

Manual: page 4

How do I manually defrost an LA135 or LA400?

LA135 and LA400 have no automatic defrost. Turn the unit off periodically, usually overnight, so evaporator frost melts.

Manual: page 4

Williams Commercial Refrigerator compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

Williams Commercial RefrigeratorSummit AL57GTrue Commercial RefrigeratorGram Commercial Refrigerator
Wait before useat least 1 hourat least 2 hours24 hoursat least 2 hours
Door-open alarm after5 minutes60 seconds≥ 60 secmore than 2 minutes
Clearance above500mm2 to 3 mm (about 1/10")1" (25.4 mm)250 mm (9.8 in)
Clearance at the sides50mm5 inches (127mm) (12.7 cm)0" (0 mm)20 mm (0.8 in)