Key numbers from this manual
As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.
| Fridge factory setting | optimum temperatures for food safetyfactory settingTypical for commercial refrigeration: 35 to 38 °F (2 to 3 °C) | p. 6 |
|---|---|---|
| Wait before use | 24 hoursunit transported on its side | p. 5 |
| Clearance at the sides | 6” needs more space than mostfor best performanceTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm) | p. 5 |
| Clearance behind | 6” needs more space than mostfor best performanceTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm) | p. 5 |
| Defrost | automatic defrost systemrefrigeration unitautomaticrefrigeration unit | p. 7 |
| Room temperature range | less than 75 °F (24 °C)temperature-controlled operating environmentTypical for commercial refrigeration: 60 to 100 °F (16 to 38 °C) | p. 5 |
Avantco 360GSM32HCB questions
Answers taken from this manual. Each one links to the page it comes from.
How do I adjust the refrigerator temperature?
Use the digital controller behind the front panel.
- Carefully pop off the front panel to access the temperature controller.
- Press SET; the set temperature appears.
- Use the temperature adjustment controls to change the displayed value.
- Press SET to exit adjustment and display the current temperature.
- If no button is pressed within 10 seconds, the current temperature appears automatically.
- Carefully replace the front panel after adjusting the temperature.
Manual: page 6
Why is condensation collecting on the cabinet or floor?
- Door slightly ajar. Close the door completely.
- Gasket not sealing properly. Clean, repair, or replace the gasket.
- Relative humidity above 55%. Move the unit to lower humidity or lower the humidity level.
Manual: page 9
What should I do if the evaporator coil is iced over?
- Unplug the unit and let the coil defrost.
- Check that the thermostat is not set too cold.
- Check that the door gaskets seal properly.
Manual: page 9
How long should I wait before plugging the refrigerator back in?
At least 10 minutes after unplugging, to prevent compressor damage.
Manual: page 7
The compressor is not running. What should I check first?
Check the fuse or breaker, power cord, thermostat setting, and defrost cycle.
- Fuse or circuit breaker is tripped. Replace the fuse or reset the circuit breaker.
- Power cord is unplugged. Plug in the power cord.
- Thermostat is set too high. Set the thermostat to a lower temperature.
- Cabinet is defrosting. Wait for the defrost cycle to finish.
Manual: page 9
Avantco 360GSM32HCB compared with other brands
Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.
| Avantco 360GSM32HCB | Other Commercial Refrigerator | Summit FF64BCSS | Whynter CBM-815WS | |
|---|---|---|---|---|
| Wait before use | 24 hours | at least 24 hours | about 2 hours | about 4 hours |
| Clearance at the sides | 6” | 2" (5.1 cm) | 5” (127mm) | at least 5 inches (127mm) (12.7 cm) |
| Clearance behind | 6” | 2" (5.1 cm) | 5” (127mm) | at least 5 inches (127mm) (12.7 cm) |
| Room temperature range | less than 75 °F (24 °C) | below 90 °F (32 °C) | above 44 °F (7 °C) and below 90 °F (32 °C) | 72º- 78ºF / 23º26ºC |
Similar Avantco commercial refrigeration
| Avantco 360CRR2HCBModel family 360 | User Manual | 7 pages |
|---|---|---|
| Avantco 360CFM2Model family 360 | User Manual | 7 pages |
| Avantco 342BRC84SZ | User Manual | 12 pages |
| Avantco 178SSPPT1 | User Manual | 13 pages |
| Avantco 178APPT49HC | User Manual | 12 pages |
| Avantco 178A23FHC | Owner's Manual | 10 pages |
| Avantco 178SSUC27FHC | User Manual | 10 pages |
| Avantco 178Z1F2A | Owner's Manual | 10 pages |