Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Clearance aboveno additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 8
Clearance at the sidesno additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 8
Clearance behindno additional air spacebuilt-in installationTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 8
Room temperature range50 °F (10 °C) and 100 °F (38 °C)Typical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 6

U-Line UCWC515-SG33A questions

Answers taken from this manual. Each one links to the page it comes from.

How do I check the actual temperature inside this unit?

Use a water bottle and thermometer, then adjust the control only after testing.

  1. Partially fill a plastic, nonbreakable bottle with water.
  2. Insert an accurate thermometer and tighten the cap securely.
  3. Place the bottle in the desired area for 24 hours.
  4. Avoid opening the unit during the test.
  5. After 24 hours, check the water temperature.
  6. If needed, adjust the temperature control in a small increment.

Manual: page 28

Why is the unit not cold enough?
  • Temperature setting. Adjust the temperature to a cooler set point.
  • Excessive ambient heat or direct sunlight. Move the unit away from those conditions.
  • Door seal. Check that the door closes and seals properly.
  • Interior light. Check that it has not remained on too long.
  • Airflow restriction or dirt. Clear the front grille and clean the condenser coil.

Manual: page 27

Why is frost forming on the internal surfaces?

A door that fails to close or seal properly can cause internal frost; check the door seal and closing action.

Manual: page 27

Why is condensation forming on the outside?

Excessive humidity causes external condensation; the moisture should disappear as humidity levels decrease.

Manual: page 27

The lights and controls work, but the compressor and fans do not. Why?

SHOWROOM MODE may be active. Hold the Light Button and Power Button for 5 seconds to exit.

Manual: page 41

Why is the ice maker producing less ice?

Higher ambient temperatures can reduce ice production. Operate the unit between 50 °F (10 °C) and 100 °F (38 °C), away from sunlight and heat-producing equipment.

Manual: page 6

What clearances does built-in installation require?

No extra top, side, or rear air space is needed; leave the front grille unobstructed and allow room for the rear electrical connection.

Manual: page 8

Can I install the unit behind a closed cabinet door?

No. The unit cannot be installed behind a closed cabinet door.

Manual: page 8

What do the displayed U-Line error codes mean?

The log records errors in occurrence order; only door errors appear on the display and produce an audible signal.

CodeMeaning
E0Door 1 (upper) open
E1, E2Thermistors 1 and 2 open
E3, E4E3 open; E4 not this model
E5, E6Thermistors 1 and 2 shorted
E7, E8E7 shorted; E8 not this model
E9, P1E9 lower door open; P1 not this model

Manual: page 42, page 43

How do I view or clear the error log?
  • Select VIEW ERROR LOG; recorded errors scroll in the order they occurred.
  • Press and hold for 5 seconds while CLR flashes to clear errors.

Manual: page 42, page 43

Error codes in this manual

CodeMeaningWhat to do
E0Upper door 1 is open.p. 42
E1Thermistor 1 is open.p. 42
E2Thermistor 2 is open.p. 42
E3Thermistor 3 is open.p. 43
E4Thermistor 4 is open; this does not apply to this model.p. 43
E5Thermistor 1 is shorted.p. 43
E6Thermistor 2 is shorted.p. 43
E7Thermistor 3 is shorted.p. 43
E8Thermistor 4 is shorted; this does not apply to this model.p. 43
E9Lower door 2 is open.p. 43
P1Pump circuit is open; this does not apply to this model.p. 43
All U-Line error codes →

Similar U-Line commercial refrigeration

U-Line UCWC515-SS33AModel family UCWC515SUser Manual49 pages
U-Line UCWC518-SS33AModel family UCWC51User Manual49 pages
U-Line UCWC518-SG33AModel family UCWC51User Manual49 pages
U-Line UCWC524-SS33AModel family UCWC5User Manual49 pages
U-Line UCWC524-SG33AModel family UCWC5User Manual49 pages
U-Line UCRE518-SS33AUser Manual48 pages
U-Line UCRE518-SG33AUser Manual48 pages
U-Line UCRE515-SG33AUser Manual48 pages
All U-Line commercial refrigeration →