Key numbers from this manual

As printed in the manual, with metric and US units side by side. The typical range comes from all commercial refrigerator manuals on this site that print the same figure.

Door-open alarm after5 minutesdoor left openTypical for commercial refrigeration: 1 to 5 minutesp. 40
Clearance abovedoes not require additional air spacewhen built-inno additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 12 in (0 to 30.5 cm)p. 8
Clearance at the sidesdoes not require additional air spacewhen built-inno additional air spacebuilt-in installationTypical for commercial refrigeration: 0 to 4 in (0 to 10.2 cm)p. 8
Clearance behinddoes not require additional air spacewhen built-inno additional air spacebuilt-in installationTypical for commercial refrigeration: 1 to 4 in (2.5 to 10.2 cm)p. 8
DefrostAutomaticp. 27
Room temperature range50 °F (10 °C) to 100 °F (38 °C)Typical for commercial refrigeration: 60 to 100 °F (16 to 38 °C)p. 6
Sabbath modeYeswhen the unit is coolingp. 27

U-Line UCWC518-SG33A questions

Answers taken from this manual. Each one links to the page it comes from.

How do I check the actual product temperature?
  1. Partially fill a plastic, nonbreakable bottle with water.
  2. Insert an accurate thermometer.
  3. Tighten the bottle cap securely.
  4. Place the bottle in the desired area for 24 hours; avoid opening the unit.
  5. After 24 hours, check the water temperature.
  6. If needed, adjust the temperature control in a small increment.

Manual: page 28

Why is frost forming inside the unit or condensation forming outside?
  • Frost inside. Check that the door closes and seals properly.
  • Condensation outside. Excessive humidity is causing moisture; it should dissipate as humidity decreases.

Manual: page 27

How do I prevent mold and mildew odors during extended non-use?

Follow these steps during extended non-use and when the unit may be exposed to 40 °F (5 °C) or less.

  1. Remove all consumable contents.
  2. Disconnect the power cord and leave it disconnected until returning the unit to service.
  3. If ice is on the evaporator, let it thaw naturally.
  4. Clean and dry the interior, removing all water.
  5. Leave the door open at least 2" (50 mm) for ventilation.

Manual: page 26

What should I check first if the refrigerator is not cooling?
  1. Verify proper airflow through the condenser.
  2. Check whether the condenser is clean.
  3. Confirm that the condenser fan operates.

Manual: page 39

Why is the ice maker producing less ice?

Higher ambient temperatures may reduce ice production; operate the unit between 50 °F (10 °C) and 100 °F (38 °C).

Manual: page 6

Can this unit go behind a closed cabinet door?

No. The unit cannot be installed behind a closed cabinet door.

Manual: page 8

What do the error codes mean?

The error log records faults in occurrence order, and only door errors appear on the display with an audible signal.

CodeMeaning
E0Door 1 (upper) open
E9Door 2 (lower) open
E1, E2, E3Thermistor 1, 2, 3 open
E5, E6, E7Thermistor 1, 2, 3 shorted
E4, E8Thermistor 4 open or shorted, not applicable
P1Pump circuit open, not applicable

Manual: page 42, page 43

How do I clear the stored error log?

Use the error-log function in service mode.

  1. Select Clear error log in service mode.
  2. Wait until CLR is flashing.
  3. Press and hold the light key for 5 seconds.

Manual: page 42, page 43

Error codes in this manual

CodeMeaningWhat to do
E0Upper door 1 is open.p. 42
E1Thermistor 1 is open.p. 42
E2Thermistor 2 is open.p. 42
E3Thermistor 3 is open.p. 42
E4Thermistor 4 is open.p. 43
E5Thermistor 1 is shorted.p. 43
E6Thermistor 2 is shorted.p. 43
E7Thermistor 3 is shorted.p. 43
E8Thermistor 4 is shorted.p. 43
E9Lower door 2 is open.p. 43
P1Pump circuit is open.p. 43
All U-Line error codes →

U-Line UCWC518-SG33A compared with other brands

Commercial Refrigeration from other brands with the most of the same figures in their manuals. Values as printed in each manual.

U-Line UCWC518-SG33AOther 9301F-290Summit SPR627OSTrue TGO-27-POP01
Door-open alarm after5 minutes2 minutesmore than 60 seconds5 minutes
Room temperature range50 °F (10 °C) to 100 °F (38 °C)70-100 °F (-73 °C)44ºF and 90ºF (7ºC to 32ºC)60 °F (15.5 °C)

Similar U-Line commercial refrigeration

U-Line UCWC518-SS33AModel family UCWC518SUser Manual49 pages
U-Line UCWC515-SG33AModel family UCWC51User Manual49 pages
U-Line UCWC515-SS33AModel family UCWC51User Manual49 pages
U-Line UCWC524-SS33AModel family UCWC5User Manual49 pages
U-Line UCWC524-SG33AModel family UCWC5User Manual49 pages
U-Line UCRE518-SS33AUser Manual48 pages
U-Line UCRE518-SG33AUser Manual48 pages
U-Line UCRE515-SG33AUser Manual48 pages
All U-Line commercial refrigeration →